48
017-882-B0-001 Rev. E (06/2018)
2.0 Installation, Continued
Torque all nuts and bolts to 110in-lbs (12.43N-m).
Threaded Insert Terminals
1/4-20
Nut
Fig. 2-15, Battery Terminal Bolt Stack-up
Fig. 2-16, Fuse Bolt Stack-up
3/4" (19mm) x 1/4-20 Bolt
3/4" (19mm) x 1/4-20 Bolt
(M6 x 12mm Bolt for 18V4)
Battery Sense
Cable or PTS
Battery Terminal
Split Washer
Split Washer
Flat Washer
Flat Washer
Battery Cable
Battery Cable
Flat Washer
Spacer
Fuse
2.2.3 120/240V Configuration Procedure
Procedure:
1.
Remove the Inverter Module to access the Transformer Harness (see Fig. 2-17).
2.
Connect the appropriate connector to the Transformer Harness. For the 120V configuration, connect the end with
two wires. For the 240V configuration, connect the end with only one wire (see Fig. 2-18).
3.
Connect the correct power cord to the power supply (see Fig. 2-19)
Fig. 2-18, 120/240V Connector
120V
240V
p/n 744-281-20
p/n 744-281-21
Threaded insert terminals require the use of 3/4" (19mm) bolts with the exception of 18V4 batteries which require
the use of M6 x 12mm bolts. The use of 1" (25.4mm) bolts will seriously damage the battery. The only exception is
the terminal with the large spacer for the in-line fuse link. Apply NO-OX grease on all exposed connections.
CAUTION!
This procedure is for the XM3-918D-HP only.
NOTICE
:
Fig. 2-17, Transformer Harness