71
017-882-B0-001 Rev. E (06/2018)
3.0 Operation, Continued
3.3.2 Battery Information and Configuration
The top line of the display is affected by pressing a softkey. In this case, pressing Enter <ENTR> will open the BATTERY
INFO
/
BATTERYCONFIG Menu enabling the operator to set values for the following parameters.
BATTERY INFO MENU
NOTE
BATT CONFIG <ENTR>
Pressing enter goes to the Battery Configuration menu shown below
BATT VOLTS
Displays combined string voltage
CHARGER CURR
Displays Batt Current for Inverter Mode
CHARGER MODE
Displays current Charger Mode: OFF/FLOAT/REFRESH
IND BATT V
Not displayed if no DSM3/IDH4/DM3 or SAG installed
BATT TEMP
Displays battery temperatures (°C)
APPS INFO <ENTR>
Pressing enter goes to the APPS/INFO menu on APPS Tab*
SAG INFO <ENTR>
Pressing enter goes to the SAG INFO menu shown at right
BATTERY CONFIG MENU
DEFAULT
RANGE
NOTE
BATT MHOS
0
0-2550
Hidden if no APPS card is installed
BATT DATES
User programmable
BATT MODEL
OTHER
AlphaCell models listed at right
BATT STR DETECT
AUTO
AUTO / MANUAL
NUM BATT STRINGS
1
1-4
BATT CAPACITY
100AH
0*, 1–1000
Automatically set when AlphaCell model is selected.
FLOAT
2.27V/C
2.10-2.35
ACCEPT
2.40V/C
2.20-2.45
REFRESH
2.45V/C
2.40-2.50
REST ENABLE
OFF
ON/OFF
TEMP COMP
5.0MV
0-5.0MV per cell
EOD TYPE
STRING
IND or STRING
Individual Battery EOD only if sense harness is connected
Will display STR OVER for STRING override mode
EOD VOLT
1.75V/C
Hidden if EOD TYPE = STRING
REFRESH ENABLE
ON
ON/OFF
Pressing Enter goes to adjust screen
SAG OPTION
AUTO
Auto-recognize Smart AlphaGuard (SAG)
SAG FW V1.00.0
Hidden if no SAG connected
SAG #####
Hidden if no SAG connected
HEATER MAT
NO
YES/NO
Pressing Enter goes to adjust screen
AlphaCell Batteries
OTHER
NO BATT*
4.0HP
3.5HP
240XTV
195XTV
150XTV
100XTV
220GXL
195GXL
165GXL
195GOLD
220GOLD
180GXL
210GXL
170XLT
18V4XTV
INDIVIDUAL
BATTERY
VOLTS MENU
BATT A1 VOLTS*
BATT A2 VOLTS*
BATT A3 VOLTS*
BATT B1 VOLTS*
BATT B2 VOLTS*
BATT B3 VOLTS*
BATT C1 VOLTS*
BATT C2 VOLTS*
BATT C3 VOLTS*
BATT D1 VOLTS*
BATT D2 VOLTS*
BATT D3 VOLTS*
NO BATTERIES**
SAG INFO
BALANCING STR*
DUR REMAIN ###### M**
A MAX DELTA #### mV**
B MAX DELTA #### mV**
C MAX DELTA #### mV**
D MAX DELTA #### mV**
A BAL STAGE MODERATE**
B BAL STAGE MODERATE**
C BAL STAGE MODERATE**
D BAL STAGE MODERATE**
A SEVERE DUR ##### M**
B SEVERE DUR ##### M**
C SEVERE DUR ##### M**
D SEVERE DUR ##### M**
BALANCER DIS YES/NO
POWERSAVE MODE YES/NO
NUM OF STRINGS ##
SAG HARDWARE ID
* Displays NONE if no strings
are being balanced
** Displays only if string is
present
* Displays only if
battery is present
** Displays if no
batteries are
present
* Displays only if Apps Card is installed
* BATT CAPACITY should only be set to "0" when no batteries are present to disable NO BATT Alarm.
* NO BATT will display
instead of OK BATT if
this is selected
120V/9.6A
89V/10.4A
OPERATION NORMAL
OK
PWR
OK
BATT
OK
COMM
OK
APPS