Tripp Lite
1111 West 35th Street
Chicago, IL 60609 USA
Telephone: +(773) 869 1234
E-mail:
Model #: SU2200XLNAFTA
SmartOnline Expandable Tower UPS System - NAFTA assembled version of SU2200XLa
Highlights
2200VA / 2.2kVA on-line, double-conversion, extended-run tower UPS
Maintains sine-wave 110/120V +/-2% output during overvoltages to 138 and
brownouts as low as 65V (50/60Hz auto-sensing)
Simultaneous communications via HID compliant USB port, serial port,
SNMP/Web card slot and EPO interface
Fault tolerant auto-bypass mode, current monitoring and switched PDU control
via 2 switchable output load banks
Input: NEMA 5-20P (120V, optional 5-15P included) / Output: 6 NEMA
5-15/20R and 1 NEMA L5-20R (120V)
$250,000
Ultimate Lifetime Insurance
(USA and Canada Only)
Description
2200VA on-line, double-conversion UPS system for critical server, network and telecommunications equipment. Upright tower form factor.
Expandable battery runtime with optional BP48V60-3UNAFTA external battery packs. Full-time sine wave 110 or 120V +/-2% output. Online,
double-conversion Uninterruptible Power Supply (UPS) actively converts raw incoming AC power to DC, then re-converts output back to completely
regulated, filtered AC output. Operates continuously without using battery power during brownouts to 65V and overvoltages to 138V. NEMA 5-20P
input plug (optional 5-15P inlcuded); NEMA 5-15/20R and NEMA L5-20R output receptacles. Network-grade AC surge and noise suppression. Zero
transfer time between AC and battery operation. Network management interfaces support simultaneous communications via USB port, DB9 serial
port and SNMPWEBCARD slot. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of
Windows and Mac OS X. Supports simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all 3
network interfaces. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. Integrated 2-bank PDU
switching supports load shedding and remote-reboot of connected equipment. 3-stage metered current monitoring and battery charge status LEDs.
Dataline surge suppression for dialup, DSL or network Ethernet connection. Utility power and voltage regulation LEDs. Audible alarm. Self-test.
Fault-tolerant auto-bypass mode. Field-replaceable, hot-swappable internal batteries and external battery packs. Attractive all-black color scheme.
$250,000
connected equipment insurance
;
Package Includes
SU2200XLNAFTA UPS System
PowerAlert Software and cabling
Instruction manual with warranty information
Features
SmartOnline high performance UPS system is ideal for critical voice, data, medical and industrial network applications
True on-line, double-conversion UPS provides perfectly regulated sine wave output within 2% of 110/120V (user selectable) under all usage
conditions
Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time
Removes harmonic distortion, fast electrical impulses, frequency variations and other hard to solve power problems not addressed by other
UPS types
Corrects line voltage conditions as low as 65V and as high as 138V back to selectable 110/120V (+/-2%) values