background image

 

Tripp Lite

1111 West 35th Street

Chicago, IL 60609 USA

Telephone: +(773) 869 1234

E-mail: 

[email protected]

Model #: SU2200XLNAFTA

SmartOnline Expandable Tower UPS System - NAFTA assembled version of SU2200XLa

 

Highlights

2200VA / 2.2kVA on-line, double-conversion, extended-run tower UPS

Maintains sine-wave 110/120V +/-2% output during overvoltages to 138 and

brownouts as low as 65V (50/60Hz auto-sensing)

Simultaneous communications via HID compliant USB port, serial port,

SNMP/Web card slot and EPO interface

Fault tolerant auto-bypass mode, current monitoring and switched PDU control

via 2 switchable output load banks

Input: NEMA 5-20P (120V, optional 5-15P included) / Output: 6 NEMA

5-15/20R and 1 NEMA L5-20R (120V)

$250,000 

Ultimate Lifetime Insurance

 (USA and Canada Only)

Description

2200VA on-line, double-conversion UPS system for critical server, network and telecommunications equipment. Upright tower form factor.

Expandable battery runtime with optional BP48V60-3UNAFTA external battery packs. Full-time sine wave 110 or 120V +/-2% output. Online,

double-conversion Uninterruptible Power Supply (UPS) actively converts raw incoming AC power to DC, then re-converts output back to completely

regulated, filtered AC output. Operates continuously without using battery power during brownouts to 65V and overvoltages to 138V. NEMA 5-20P

input plug (optional 5-15P inlcuded); NEMA 5-15/20R and NEMA L5-20R output receptacles. Network-grade AC surge and noise suppression. Zero

transfer time between AC and battery operation. Network management interfaces support simultaneous communications via USB port, DB9 serial

port and SNMPWEBCARD slot. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of

Windows and Mac OS X. Supports simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all 3

network interfaces. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. Integrated 2-bank PDU

switching supports load shedding and remote-reboot of connected equipment. 3-stage metered current monitoring and battery charge status LEDs.

Dataline surge suppression for dialup, DSL or network Ethernet connection. Utility power and voltage regulation LEDs. Audible alarm. Self-test.

Fault-tolerant auto-bypass mode. Field-replaceable, hot-swappable internal batteries and external battery packs. Attractive all-black color scheme.

$250,000 

connected equipment insurance

;

Package Includes

SU2200XLNAFTA UPS System 

PowerAlert Software and cabling

Instruction manual with warranty information

Features

SmartOnline high performance UPS system is ideal for critical voice, data, medical and industrial network applications

True on-line, double-conversion UPS provides perfectly regulated sine wave output within 2% of 110/120V (user selectable) under all usage

conditions

Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time

Removes harmonic distortion, fast electrical impulses, frequency variations and other hard to solve power problems not addressed by other

UPS types

Corrects line voltage conditions as low as 65V and as high as 138V back to selectable 110/120V (+/-2%) values

Reviews: