802953
94
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT
Error Codes
The following table is a list of possible error codes for
an electronic control. Errors beginning with “EI” refer
to external device Infra-red communication errors.
Errors beginning with “EC” refer to card reader errors.
All other errors refer to machine errors.
Display
Description
Cause/
Corrective Action
EI01
Transmission Failure
Communication failure. Re-aim external device and try
again.
EI02
Time-out Error
Communication failure. Re-aim external device and try
again.
EI03
Invalid Command Code
Communication successful, but the command was not
valid for this machine type, or the control could not
perform the command in its current mode of operation.
Ensure data is for current machine type and control is in
correct mode.
EI04
Expecting Upload Request
Communication failure. Re-aim external device and try
again.
EI05
Invalid or Out-of-Range Data
The value in at least one of the programming options is
invalid or out of range. Recheck the programming
option’s value and try again.
EI09
CRC-16 Error
Communication failure. Re-aim external device and try
again.
EI0A
Framing Error
Communication error. Re-aim external device and try
again.
EI0C
Time-out Exceeded
Communication error. Re-aim external device and try
again.
EI0E
Encryption Error
Communication error. Re-aim external device and try
again. If the problem persists, check that the security
code is correct.
EI0F
Infra-red Disabled
Communication failure or infra-red is disabled.
Manually enable infra-red on control or re-aim external
device and try again.
EC02
Time-out Error
Communication failure. Try card again.
EC03
Invalid Command Code
Communication successful, but the command was not
valid for this machine type, or the control could not
perform the command in its current mode of operation.
Ensure data is for current machine type and control is in
correct mode.
EC05
Invalid or Out-of-Range Data
The value in at least one of the programming options is
invalid or out of range. Recheck the programming
option’s value and try again.
EC11
No Card Reader Initialization
Communication is valid, but there is no card reader
initialization. Power down, power up and try again.