Testing Machine and Electronic Control Functions
802953
92
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT
Production Test Cycle Quick Reference Chart
Display
Test Mode
Comments
S XX
Software Version
XX
is the software version number.
CtXX
Control Type
XX
is the control type.
FL X
Machine Type
X
is either P for pump equipped machines or d for gravity drain equipped
machines.
8888
Display Test
All LEDs and display segments will light.
PAdX
Keypad Test
When a key is pressed, the control will display the number assigned to the
keypad [
X
is 1 – NORMAL 90, 2 – NORMAL 60, 3 – NORMAL 40, 4 –
SOIL LEVEL, 5 – PERM PRESS 60, 6 – DELICATES 30, 7 –
DELICATES COLD, 8 – START (enter)]. As each keypad is pressed, its
corresponding LED will be lit and remain on for the duration of the test.
When all keypads have been pressed, the control will advance to Door
Switch Test step.
droP or drCL
Door Switch Test
droP
is displayed when loading door is open.
drCL
is displayed when
loading door is closed.
drLo or drUL
Door Lock Test
When step is entered, control will lock door and will then check to make
sure door is locked.
drLo
is displayed if door is locked.
drUL
is displayed
if door is unlocked.
U oP or U CL
Coin Vault Test
U oP
is displayed when coin vault switch is open.
U CL
is displayed when
coin vault switch is closed.
S oP or S CL
Service Door Switch Test
S oP
is displayed when service door switch is open.
S CL
is displayed
when service door switch is closed.
CXCX
Coin Drop Test
X
is the number of coins entered. Coin drop #1 is shown on the left of the
display and coin drop #2 is shown on the right of the display.
CLdE
Cold/Detergent Fill
Cold Water Fill valve and Detergent/Bleach valve are turned on.
HoSF
Hot/Softener Fill
Hot Water Fill valve and Softener valve are turned on.
PS
(software
version “S 01”)
PSL
(software
version “S 02” or
higher)
Pressure Switch Test
Both water valves are turned on. When the pressure switch level is
satisfied, the water valves are turned off. The control will not advance to
next step until pressure switch level is satisfied and START (enter) keypad
is pressed.
C XX
Heater Test
This step checks heater operation.
XX
is the temperature in degrees
Celsius.
oFLo
Overflow Test
All water and dispenser valves are turned on. When the overflow level is
reached the water valves are turned off.
LoAg
Low Agitate
Machine enters low agitate.
rEAg
Regular Agitate
Machine enters regular agitate.
Table 18 (continued)