© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT
Programming Control
79
802953
29. Low Power/Auto Shutdown D
Days Enable “LPSd”
This option allows the owner to set Low Power/Auto
Shutdown on certain day(s) of the week. Low Power
or Auto Shutdown duration are programmed using an
external device or network.
How to Program the Low Power/Auto
Shutdown D Days Enable
1. Control must be in Manual Mode. Refer to
Entering the Manual Mode
.
2. Press the NORMAL 40 ( ) or the DELICATES
COLD ( ) keypad until “
Prog
” appears in the
display. Press the START (enter) keypad and
“
AtS1
” will appear in the display.
3. Press the NORMAL 40 ( ) or the DELICATES
COLD ( ) keypad to scroll through the
programmable options until “
LPSd
” appears in
the display.
4. When “
LPSd
” appears in the display, press the
START (enter) keypad. The current Low Power/
Auto Shutdown D Days Enable status will appear
in the display.
“
on
” = Option Enabled
“
oFF
” = Option Disabled (factory default
setting)
5. Press the NORMAL 40 ( ) or the DELICATES
COLD ( ) keypad to change the current status.
6. Press the START (enter) keypad when the correct
status appears in the display. The next option,
“
PFr
”, will appear in the display.
NOTE: To program
“PFr”
(Power Fail Reset),
refer to
option 30
. To program other options, refer
to the appropriate section.
How to Exit Programming Feature
Press the DELICATES 30 (<) keypad until the control
returns to Ready Mode.
30. Power Fail Reset “PFr”
This option allows the owner to set the amount of time
the control will store active cycle information in the
event of a power failure. The default setting for Power
Fail Reset is OFF. If Power Fail Reset is turned OFF,
the cycle will be saved.
How to Program Power Fail Reset
1. Control must be in Manual Mode. Refer to
Entering the Manual Mode
.
2. Press the NORMAL 40 ( ) or the DELICATES
COLD ( ) keypad until “
Prog
” appears in the
display. Press the START (enter) keypad and
“
AtS1
” will appear in the display.
3. Press the NORMAL 40 ( ) or the DELICATES
COLD ( ) keypad to scroll through the
programmable options until “
PFr
” appears in the
display.
4. When “
PFr
” appears in the display, press the
START (enter) keypad. “
oFF
” or a number will
appear in the display. This number corresponds to
the current Power Fail Reset setting.
5. Press the NORMAL 40 ( ) or the DELICATES
COLD ( ) keypad to increase or decrease the
current number to the desired number selected
from
Table 13
.
6. Press the START (enter) keypad when the correct
number appears in the display. The next option,
“
IrA
”, will appear in the display.
NOTE: To program
“IrA”
(IR Access [On/Off]),
refer to
option 31
. To program other options, refer
to the appropriate section.
How to Exit Programming Feature
Press the DELICATES 30 (<) keypad until the control
returns to Ready Mode.
>
<
>
<
>
<
>
<
>
<
>
<
Summary of Contents for ST3LXFSP401NW22
Page 2: ......