Programming Control
802953
30
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT
6. Available Type “AtyP”
This option allows the owner to program when the
control provides an available output for card and
central pay systems.
How to Program Available Type
1. Control must be in Manual Mode. Refer to
Entering the Manual Mode
.
2. Press the NORMAL 40 ( ) or the DELICATES
COLD ( ) keypad until “
Prog
” appears in the
display. Press the START (enter) keypad and
“
AtS1
” will appear in the display.
3. Press the NORMAL 40 ( ) or the DELICATES
COLD ( ) keypad to scroll through the
programmable options until “
AtyP
” appears in
the display.
4. When “
AtyP
” appears in the display, press the
START (enter) keypad. A number will appear in
the display. This number corresponds to the
current Available Type Value.
5. Press the NORMAL 40 ( ) or the DELICATES
COLD ( ) keypad to increase or decrease the
current number to the desired number selected
from
Table 2
.
6. Press the START (enter) keypad when the correct
number appears in the display. The next option,
“
dCYC
”, will appear in the display.
NOTE: To program
“dCYC” (
Default Cycle), refer
to
option 7
. To program other options, refer to the
appropriate section.
How to Exit Programming Feature
Press the DELICATES 30 (<) keypad until the control
returns to Ready Mode.
>
<
>
<
Available Type
Value
Mode(s) in Which Available
Signal is Active
0*
Ready Mode only
1
Ready Mode, Partial Vend Mode
2
Ready Mode, End of Cycle Mode
3
Ready Mode, End of Cycle Mode,
Partial Vend Mode
*Factory default setting.
Table 2
>
<
Summary of Contents for ST3LXFSP401NW22