© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT
Error Codes
95
802953
Table 19 (continued)
Display
Description
Cause/
Corrective Action
EC18
No Communication
Card reader is initialized, communication lost. Power
down, power up and try again. If error persists, replace
control or card reader.
EC19
No Card Reader Communication
Communication failure. Power down, power up and try
again. If error persists, replace control or card reader.
Right most
decimal
point Lit
Network Communication Error
Communication problem. Wait 1.5 minutes for error to
clear. If error doesn’t clear, power down and power up
the machine. If error persists, replace control or network
board.
ALrn
Break-in Alarm Error
Service the door or coin vault switches.
oFF
Break-in Alarm Shutdown Error
Service the door or coin vault switches.
E FL
Fill Error
Pressure switch fails to open in 30 minutes (or other
programmed length of time) in any fill agitate cycle.
E SP
SPI Communications Error
Master control cannot communicate with motor control.
Caused by transformer unplugged or wiring to motor
control incorrect. Power down the machine, power up
and try again.
E dL
Door Lock Error
Door does not lock within 15 seconds of closing (open
and reclose door) or doesn’t unlock 3 minutes after cycle
completion.
E do
Door Opened During A Running Cycle
Control detects door open and door locked inputs high.
Caused by pulling on door while locked or about to lock.
Correct inoperative door locking system.
E Ub
Unbalance Error
Unable to balance load. Redistribute load and run cycle.
E dF
Drive Failure
Motor unplugged, motor failure, tachometer circuit open
or drum locked up. Unpower machine to reset.
door
Door Open Indicator
Door is not closed during an active cycle. If door is
closed, check for improper wiring or faulty door switch.
E rr
Coin Error
Invalid coin pulse or inoperative coin sensor. Check coin
drop area and remove obstructions. If error persists,
tampering may have occurred. Evaluate security
procedures.
E oP
Open Thermistor Error
Thermistor circuit opens while heating. Heater will turn
off and cycle will continue.
E SH
Shorted Thermistor Error
Thermistor circuit is shorted while heating. Heater will
turn off and cycle will continue.
E Ht
Heater Error
Programmed temperature hasn’t been reached in more
than two hours. Cycle will continue with heater off.
Table 19
Summary of Contents for ST3LXFSP401NW22