© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT
85
802953
Testing Machine and
Electronic Control Functions
This feature allows the owner to run diagnostic tests
on various washer operations without servicing the
washer. The following tests are available:
Control Software Version Number
Service Door Opening Test
Coin Vault Opening Test
Coin Drop #1 Input Test
Coin Drop #2 Input Test
Coin Drops Header Present Test
(software version “S 02” or higher only)
Door Switch Input Test
Door Lock Input Test
Pump/Gravity Drain Test
Show Fill Time Test
Temperature Sensor Display Test
Start Pulse Test
Configuration #1 Display Test
Configuration #2 Display Test
For an overview of the manual diagnostic test feature,
refer to the flowchart on the following page.
How to Enter Testing Feature
1. Control must be in Manual Mode. Refer to
Entering the Manual Mode
.
2. Press the NORMAL 40 ( ) or the DELICATES
COLD ( ) keypad until “
dIAg
” appears.
3. Press the START (enter) keypad. Display will
change to “
d001
” indicating the control software
version number test.
4. Press the NORMAL 40 ( ) or the DELICATES
COLD ( ) keypad to scroll through the
diagnostic test options.
How to Start Tests
To start a diagnostic test, refer to the quick reference
charts below (
Table 15 or Table 16
). Press the START
(enter) keypad when the desired test number is
displayed. For detailed information on each test, read the
appropriate description.
How to Exit Testing Feature
Press the DELICATES 30 (<) keypad until the display
returns to the previous mode of operation.
>
<
>
<
Diagnostic (Testing) Mode – Quick Reference Chart
Software Version “S 01”
Test Number
Diagnostic Mode
Display
“d001”
Control Software Version # Test
“SXX”
“d002”
Service Door Opening Test
“SXX”
“d003”
Coin Vault Opening Test
“UXX”
“d004”
Coin Drop #1 Input Test
“C1XX”
“d005”
Coin Drop #2 Input Test
“C2XX”
“d006”
Door Switch Input Test
“drCL” or “droP”
“d007”
Door Lock Switch Input Test
“drUL” or “drLo”
“d008”
Pump/Gravity Drain Test
“PunP” or “drAi”
“d009”
Show Fill Time Test
“FXXX”
“d010”
Temperature Sensor Display Test
“C XX”
“d011”
Start Pulse Test
“StXX”
“d012”
Configuration #1 Display Test
“A0XX”
“d013”
Configuration #2 Display Test
“b0XX”
Table 15
Summary of Contents for ST3LXFSP401NW22
Page 2: ......