Programming Control
802953
38
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT
How to Enter Cycle Programming
1. Control must be in Manual Mode. Refer to
Entering the Manual Mode
.
2. Press the NORMAL 40 ( ) or the DELICATES
COLD ( ) keypad until “
Prog
” appears in the
display. Press the START (enter) keypad and
“
AtS1
” will appear in the display.
3. Press the NORMAL 40 ( ) or the DELICATES
COLD ( ) keypad to scroll through the
programmable options until “
CyC-
” appears in
the display. Press the START (enter) keypad and
“
CyC1
” will appear in the display.
NOTE: The LED light next to the select cycle
keypad will be lit to indicate which cycle is being
programmed.
4. Press the NORMAL 40 ( ) or the DELICATES
COLD ( ) keypad to scroll through the six cycles
to program. Press the START (enter) keypad
when the desired cycle appears in the display.
5. The first Cycle Programming option, “
StA1
”,
will appear in the display.
NOTE: To program
“StA1”
(Cycle Stage),
continue to next option. To program other options,
press the DELICATES 30 (<) keypad and refer to
the appropriate section.
How to Exit Programming Feature
Press the DELICATES 30 (<) keypad until the control
returns to Ready Mode.
How to Program Cycle Stages “StAx”
There are eight programmable cycle stages. Within
each stage, there are three programmable options.
1. Press the NORMAL 40 ( ) or the DELICATES
COLD ( ) keypad to scroll through the eight
programmable Cycle Stages until the desired
stage appears in the display.
2. When the desired stage appears in the display,
press the START (enter) keypad. “
StEn
” (Cycle
Stage Enable) will appear in the display.
3. Press the NORMAL 40 ( ) or the DELICATES
COLD ( ) keypad to scroll through the Cycle
Stage programmable options.
NOTE: If the Cycle Stage Enable is programmed
“
oFF
”, the other Cycle Stage programming options
can’t be accessed.
4. Press the START (enter) keypad when the
desired Cycle Stage programmable option
appears in the display.
Programming Cycle Stage Enable
1. When “
StEn
” appears in the display, press the
START (enter) keypad. The current Cycle Stage
Enable/Disable status will appear in the display.
“
on
” = Cycle Stage is enabled (factory default
setting for stages 4, 6 and 8)
“
oFF
” = Cycle Stage is disabled (factory default
setting for stages 1-3, 5 and 7)
2. Press the NORMAL 40 ( ) or the DELICATES
COLD ( ) keypad to change the current status.
NOTE: If the Cycle Stage enable is programmed
“
oFF
”, the other Cycle Stage programming options
can’t be accessed.
3. Press the START (enter) keypad when the
desired status appears in the display. The next
Cycle Stage option, “
AgIt
”, will appear in the
display if option is enabled.
NOTE: To program
“AgIt”
(Fill/Agitate Step),
continue to next Cycle Stage option. To program
other options, press the DELICATES 30 (<) keypad
and refer to the appropriate section.
How to Exit Programming Feature
Press the DELICATES 30 (<) keypad until the control
returns to Ready Mode.
>
<
>
<
>
<
>
<
>
<
>
<
Summary of Contents for ST3LXFSP401NW22
Page 2: ......