Chapter 4
CIP Axis Attributes
404
Rockwell Automation Publication MOTION-RM003I-EN-P - February 2018
The Induction Motor Rated Slip Speed attribute represents the amount of slip at
motor rated current (full load) and motor rated frequency.
See also
General Permanent Magnet Motor Attributes
These are the motor configuration attributes that apply specifically to linear PM
motor types.
PM Motor Rated Force
Usage
Access
Data
Type
Default
Min
Max
Semantics of Values
Optional
Set/GSV
REAL
0
DB
0
N
The PM Motor Rated Force attribute is a floating point value that specifies the
nameplate continuous force rating of a linear permanent magnet motor in
Newtons (N).
PM Motor Force Constant
Usage
Access
Data
Type
Default
Min
Max
Semantics of Values
Optional
Set/SSV*
REAL
0
0
DB
N/Amp (RMS)
*
Indicates the attribute cannot be set while the drive power structure is enabled (Power Structure Enable bit in CIP Axis Status
is true).
The PM Motor Force Constant attribute is a floating point value that specifies the
force constant of a linear permanent magnet motor in Newtons per RMS Amp.
PM Motor Linear Voltage Constant
Usage
Access
Data
Type
Default
Min
Max
Semantics of Values
Required
Set/SSV*
REAL
0
DB
0
Volts (RMS) / (m/s)
*
Indicates the attribute cannot be set while the drive power structure is enabled (Power Structure Enable bit in CIP Axis Status
is true).