Chapter 3
Interpret the Attribute Tables
128
Rockwell Automation Publication MOTION-RM003I-EN-P - February 2018
ID
Access
Rule
Attribute
B
E
F
P
V
T
Conditional Implementation
445
Set
Position Error Tolerance Time
-
-
Y
-
-
365
Get
Position Fine Command
-
-
Y
-
-
446
Set
Position Integrator Control
-
-
R
-
-
O-Bit
1: Auto-Preset (N)
447
Set
Position Integrator Preload
-
-
N
-
-
781
Set
Position Lead Lag Filter Bandwidth
-
-
Y
-
-
782
Set
Position Lead Lag Filter Gain
-
-
Y
-
-
783
Set
Position Notch Filter Frequency
-
-
N
-
-
627
Set
Power Loss Action
-
N
N
N
N
O-Enum
2 = Decel Regen (N)
628
Set
Power Loss Threshold
N
-
N
N
N
N
630
Set
Power Loss Time
N
-
N
N
N
N
590
Set
Proving Configuration
-
Y5
Y
Y
Y
V26/V27
376
Set*
Ramp Acceleration
-
N
-
N
-
Derived
377
Set*
Ramp Deceleration
-
N
-
N
-
Derived
378
Set
Ramp Jerk Control
-
N
-
N
-
375
Set*
Ramp Velocity - Negative
-
N
-
N
-
Derived
374
Set*
Ramp Velocity - Positive
-
N
-
N
-
Derived
613/354
Set
Resistive Brake Contact Delay
-
N
N
N
N
PM Motor only
1333
Set
Rotary Motor Damping Coefficient
-
N
N
N
N
Rotary Motor only
2312
Set
Rotary Motor Fan Cooling Derating
-
N
N
N
N
Rotary Motor only
2311
Set
Rotary Motor Fan Cooling Speed
-
N
N
N
N
Rotary Motor only
1330
Set
Rotary Motor Inertia
-
N
Y
Y
Y
Rotary Motor only
1332
Set
Rotary Motor Max Speed
-
Y
Y
Y
Y
Rotary Motor only
765
Set
Safe Torque Off Action
-
N
N
N
N
0-Enum
1 = Current Decel Disable (F/N)
2 = Ramped Decel Disable (FV/N) 128 = DC Injection Brake
(FPVT/N) 129 = AC Injection Brake (FPVT/N)
629
Set
Shutdown Action
N
-
N
N
N
N
O-Enum
1 = Drop DC Bus (FPVT/N)
370
Set
Skip Speed 1
-
Y
-
-
-
371
Set
Skip Speed 2
-
Y
-
-
-
372
Set
Skip Speed 3
-
N
-
-
-
373
Set
Skip Speed Band
-
Y
-
-
-
833
Set
SLAT Configuration
-
-
-
Y
-
834
Set
SLAT Set Point
-
-
-
Y
-
835
Set
SLAT Time Delay
-
-
-
Y
-
610
Set
Stopping Action
-
R
R
R
R
O-Enum
1 = Current Decel Disable (F/Y) V26/V27 2 = Ramped Decel
Disable (FV/N)
3 = Current Decel Hold (PV/Y) 4 = Ramped Decel Hold (V/N)
128 = DC Injection Brake (FPVT/N) 129 = AC Injection Brake
(FPVT/N)