CIP Axis Attributes
Chapter 4
Rockwell Automation Publication MOTION-RM003I-EN-P - February 2018
313
Feedback n Length
Usage
Access
Data
Type
Default
Min
Max
Semantics of Values
Required - E
Linear Absolute
Set/GSV
REAL
1
DB
0.001
Meters
The Feedback n Length attribute is the specified length of a linear absolute
feedback device. Typical linear absolute feedback devices specify length in Meters.
This attribute can be used by the control system to determine the maximum travel
range of absolute feedback device in Feedback Counts, this being the combination
of the feedback cycle resolution, interpolation, and length.
Feedback n Data Length
Usage
Access
Data
Type
Default
Min
Max
Semantics of Values
Optional - E
TP, SS
Set/GSV
USINT
16
8
32
# of Bits
The Feedback n Data Length attribute is the number of feedback data bits
transferred over the digital serial or parallel data interface channel of a feedback
device.
Feedback n Data Code
Usage
Access
Data
Type
Default
Min
Max
Semantics of Values
Optional - E
TP, SS
Set/GSV
USINT
0
-
-
Enumeration
0 = Binary
1 = Gray
2...255 = Reserved
The Feedback n Data Code attribute is the type of feedback data bit encoding
used by designated serial or parallel data interface channel of a feedback device.
Feedback n Resolver Transformer Ratio
Usage
Access
Data
Type
Default
Min
Max
Semantics of Values
Optional - E
RS
Set/GSV
REAL
1
-
-
-
The Feedback n Resolver Transformer Ratio attribute is the Transformer Ratio
specification of the designated resolver feedback device.