Chapter 3
Interpret the Attribute Tables
156
Rockwell Automation Publication MOTION-RM003I-EN-P - February 2018
ID
Access Rule Attribute Name
B
E
F
P
V
T
Conditional Implementation
1376
Set
Actuator Diameter
N
N
N
N
N
DScale
1377
Set
Actuator Diameter Unit
N
N
N
N
N
DScale
1374
Set
Actuator Lead
N
N
N
N
N
DScale
1375
Set
Actuator Lead Unit
N
N
N
N
N
DScale
1373
Set
Actuator Type
N
N
N
N
N
DScale
732/267
Get
Analog Input 1
B
B
N
N
N
N
733/268
Get
Analog Input 2
B
B
N
N
N
N
734
Set
Analog Output 1
B
B
N
N
N
N
735
Set
Analog Output 2
B
B
N
N
N
N
30
Set
Axis Configuration
R
R
R
R
R
O-Enum
0 = Feedback Only (Y)
1 = Frequency Control (N)
2 = Position Loop (Y)
3 = Velocity Loop (Y)
4 = Torque Loop (Y)
19
Set
Axis Features
R
R
R
R
R
O-Bits
0 = Fine Interpolation (Y)
1 = Registration Auto-rearm (Y)
2 = Alarm Log (Y)
5 = Hookup Test (Y)
6 = Commutation Test (Y)
7 = Motor Test (N)
8 = Inertia Test (Y)
9 = Sensorless Control (N)
763
Get
Axis Safety Faults
O
O
O
O
Y
760
Get
Axis Safety State
O
O
O
O
Y
761
Get
Axis Safety Status
O
O
O
O
Y
825
Set
Backlash Compensation Window
-
-
Y
-
-
638/262
Get
Bus Regulator Capacity
-
N
Y
Y
Y
659
Get
CIP Axis Alarms
Y
N
Y
Y
Y
904
Get
CIP Axis Alarms - RA
Y
N
Y
Y
Y
563
Set
Commutation Polarity
-
-
Y
Y
Y
PM Motor only
562
Set
Commutation Self-Sensing Current
-
-
Y
Y
Y
PM Motor only O-Value = 100
637
Get
Converter Capacity
-
N
Y
Y
Y
840
Set
Current Disturbance
-
-
N
N
N
527
Get
Current Error
-
-
Y
Y
Y
529
Get
Current Feedback
-
-
Y
Y
Y
522
Get
Current Limit Source
-
-
Y
Y
Y
524
Get
Current Reference
-
-
Y
Y
Y
553
Set
Current Vector Limit
-
N
N
N
N
870
Set
DC Injection Brake Current
-
N
N
N
N
Ind Motor only
872
Set
DC Injection Brake Time
-
N
N
N
N
Ind Motor only
486
Set
Deceleration Limit
-
N
Y
Y
N