
Interpret the Attribute Tables
Chapter 3
Rockwell Automation Publication MOTION-RM003I-EN-P - February 2018
157
ID
Access Rule Attribute Name
B
E
F
P
V
T
Conditional Implementation
730
Get
Digital Inputs
-
N
N
N
N
731
Set
Digital Outputs
-
N
N
N
N
1435
Set
Feedback 1 Accel Filter Bandwidth
Y
-
Y
Y
Y
2404
Set
Feedback 1 Accel Filter Taps
Y
-
Y
Y
Y
2405
Set
Feedback 1 Battery Absolute
N
-
N
N
N
TM
1421
Set
Feedback 1 Data Code
N
-
N
N
N
TP,SS
1420
Set
Feedback 1 Data Length
N
-
N
N
N
TP,SS
2400
Set
Feedback 1 Loss Action
N
-
N
N
N
O-Enum
1 = Switch to Sensorless Fdbk (N)
2 = Switch to Redundant Fdbk (N)
1414
Set
Feedback 1 Polarity
Y
-
Y
Y
Y
1425
Set
Feedback 1 Resolver Cable Balance
N
-
N
N
N
RS
1424
Set
Feedback 1 Resolver Excitation Frequency
N
-
N
N
N
RS
1423
Set
Feedback 1 Resolver Excitation Voltage
N
-
N
N
N
RS
1422
Set
Feedback 1 Resolver Transformer Ratio
N
-
N
N
N
RS
1401
Get
Feedback 1 Serial Number
Y
-
Y
Y
Y
1415
Set
Feedback 1 Startup Method
R
-
R
R
R
O-Enum
1 = Absolute (Y)
1434
Set
Feedback 1 Velocity Filter Bandwidth
Y
-
Y
Y
Y
2403
Set
Feedback 1 Velocity Filter Taps
Y
-
Y
Y
Y
1485
Set
Feedback 2 Accel Filter Bandwidth
Y
-
Y
Y
Y
2454
Set
Feedback 2 Accel Filter Taps
Y
-
Y
Y
Y
2455
Set
Feedback 2 Battery Absolute
N
-
N
N
N
TM
1471
Set
Feedback 2 Data Code
N
-
N
N
N
TP,SS
1470
Set
Feedback 2 Data Length
N
-
N
N
N
TP,SS
2450
Set
Feedback 2 Loss Action
N
-
N
N
N
O-Enum
1 = Switch to Sensorless Fdbk (N)
2 = Switch to Redundant Fdbk (N)
1464
Set
Feedback 2 Polarity
Y
-
Y
Y
Y
1475
Set
Feedback 2 Resolver Cable Balance
N
-
N
N
N
RS
1474
Set
Feedback 2 Resolver Excitation Frequency
N
-
N
N
N
RS
1473
Set
Feedback 2 Resolver Excitation Voltage
N
-
N
N
N
RS
1472
Set
Feedback 2 Resolver Transformer Ratio
N
-
N
N
N
RS
1451
Get
Feedback 2 Serial Number
Y
-
Y
Y
Y
1465
Set
Feedback 2 Startup Method
R
-
R
R
R
O-Enum
1 = Absolute (Y)
1484
Set
Feedback 2 Velocity Filter Bandwidth
Y
-
Y
Y
Y
2453
Set
Feedback 2 Velocity Filter Taps
Y
-
Y
Y
Y
250
Set
Feedback Commutation Aligned
-
-
Y
Y
Y
O-Enum
2 = Motor Offset (Y)
3 = Self-Sense (Y)