The following table lists the attributes that are available to a specific drive via
messaging. The P### references in the Conditional Implementation column refer
to the related PowerFlex drive parameter.
ID
Attribute
K350
K5500 K6500 PF755 E
F
P
V
T
C/D
Conditional Implementation
480
Acceleration Command
X
X
O
O
O
MSG Access Only
1404
+(n-1
)*50
Acceleration Feedback (General Feedback
Signal)
X
X
X
R
R
R
R
E, MSG Access Only
1454 Acceleration Feedback 2
X
R
R
R
R
E, MSG Access Only
639
Ambient Temperature
O
O
O
O
MSG Access Only
688
Bus Overvoltage Factory Limit
X
O
O
O
O
MSG Access Only
686
Bus Regulator Overtemperature Factory
Limit
O
O
O
O
MSG Access Only
687
Bus Regulator Thermal Overload Factory
Limit
X
O
O
O
O
MSG Access Only
880
Bus Regulator Reference
X
O
O
O
O
MSG Access Only, P375
689
Bus Undervoltage Factory Limit
O
O
O
O
MSG Access Only
756
CIP APR Faults
C
C
C
C
Yes
R-Co CScale; O-Dr DScale; E, MSG Access
Only
757
CIP APR Faults - Mfg
C
C
C
C
Yes
Vxx; R-Co CScale; O-Dr DScale; E, MSG
Access Only
905
CIP APR Faults - RA
C
C
C
C
Yes
R-Co CScale; O-Dr DScale; E, MSG Access
Only
660
CIP Axis Alarms - Mfg
X
X
O
O
O
O
O
Vxx; MSG Access Only
673
CIP Axis Exception Action - Mfg
X
X
X
R
R
R
R
R
MSG Access Only
655
CIP Axis Exceptions
X
X
X
R
R
R
R
R
MSG Access Only
656
CIP Axis Exceptions - Mfg
X
X
X
R
R
R
R
R
Vxx; MSG Access Only
902
CIP Axis Exceptions - RA
R
R
R
R
R
Yes
MSG Access Only
658
CIP Axis Faults - Mfg
X
X
X
R
R
R
R
R
Vxx; MSG Access Only
654
CIP Axis I/O Status - Mfg
X
X
X
R
R
R
R
R
Vxx; MSG Access Only
652
CIP Axis Status - Mfg
X
X
X
R
R
R
R
R
Vxx; MSG Access Only
675
CIP Initialization Faults - Mfg
X
X
X
R
R
R
R
R
Yes
Vxx; MSG Access Only
677
CIP Start Inhibits - Mfg
X
X
X
R
R
R
R
Vxx; MSG Access Only
832
Cogging Compensation Table
O
O
O
MSG Access Only
768
Command Notch Filter Frequency
X
O
O
MSG Access Only
564
Commutation Alignment
X
X
O
O
O
E; PM Motor only, O- Enum, MSG Access
Only
900
Control Module Overtemperature Factory
Limit
O
O
O
O
O
MSG Access Only
710
Control Power-up Time
O
O
O
O
MSG Access Only
693
Converter Ground Current Factory Limit
O
O
O
O
MSG Access Only
684
Converter Overtemperature Factory Limit
O
O
O
O
MSG Access Only
901
Converter Precharge Overload Factory
Limit
O
O
O
O
MSG Access Only
723
Converter Rated Output Current
X
X
-
O
O
O
O
Yes
MSG Access Only
MSG Instruction Access Only
Attributes