Chapter 4
CIP Axis Attributes
430
Rockwell Automation Publication MOTION-RM003I-EN-P - February 2018
Guard Faults Bit Descriptions
Bit
Name
Description
0
Reserved - Combined Faults
1
Guard Internal Fault
An internal fault has been detected by the Safety Core
hardware. This can includes safety processor faults,
inter-processor communications faults, safety power supply
faults, and gate drive circuitry.
2
Guard Configuration Fault
The safety configuration data is invalid.
3
Guard Gate Drive Fault
Indicates that the Gate Drive (MP OUT) circuit used to disable
the drive power structure has detected an error.
4
Guard Reset Fault
The Safety Reset input was ON at power up.
5
Guard Feedback 1 Fault
A problem has been detected with the feedback 1 device.
6
Guard Feedback 2 Fault
A problem has been detected with the feedback 2 device.
7
Guard Feedback Speed Compare Fault
A speed miss-compare was detected between the two
feedback devices.
8
Guard Feedback Position Compare Fault A position discrepancy was detected between the two
feedback devices.
9
Guard Stop Input Fault
A fault has been detected on the Safe Stop input(s).
10
Guard Stop Output Fault
A fault has been detected on the Safe Stop cascading
outputs.
11
Guard Stop Decel Fault
A speed fault was detected during the deceleration
monitoring.
12
Guard Stop Standstill Fault
Zero speed was not detected by the end of the stop delay.
13
Guard Stop Motion Fault
Motion was detected after stop was detected and the door
unlocked.
14
Guard Limited Speed Input Fault
A fault has been detected on the Safe Limited Speed input(s).
15
Guard Limited Speed Output Fault
A fault has been detected on the Safe Limited Speed outputs.
16
Guard Limited Speed Monitor Fault
The Safe Limited Speed has been exceeded.
17
Guard Max Speed Monitor Fault
The Safe Maximum Speed has been exceeded.
18
Guard Max Accel Monitor Fault
The Safe Maximum Acceleration has been exceeded.
19
Guard Direction Monitor Fault
Motion in the restricted direction has been detected.
20
Guard Door Monitor Input Fault
A fault has been detected on the Door Monitoring input(s).
21
Guard Door Monitor Fault
The Door Monitoring inputs were detected as OFF when they
should have been ON.
22
Guard Door Control Output Fault
A fault has been detected on the Door Control outputs.
23
Guard Lock Monitor Input Fault
A fault has been detected on Lock Monitoring input(s).