Behavior models used in CIP Motion
Chapter 2
Rockwell Automation Publication MOTION-RM003I-EN-P - February 2018
53
Tip:
* Specific Standby State after a Fault Reset is determined by applying the Fault
Reset State Transition Precedence Rules.
** When an axis is in the Stopped or Major Faulted states with Holding torque (as a
result of a Category 2 Stop), a Start Inhibit condition, Disable Request, or
Shutdown Request is used to execute the configured Stopping Action.
Valid transitions for the Axis State Model are defined in the following table:
Current State
Event
Conditions
Next State
Off
Power Up
Self Test
Self Test
Self Test Complete
Initializing
Initializing
Initialization Fault
Major Faulted
Initializing
Initialization Complete
Pre-Charge
Shutdown
Major Fault
Major Faulted
Pre-Charge
Shutdown
Shutdown
Pre-Charge
Major Fault
Major Faulted
Pre-Charge
Bus Up
Stopped
Start Inhibited
Shutdown
Shutdown
Start Inhibited
Major Fault
Major Faulted
Start Inhibited
Inhibits Cleared
Stopped
Major Faulted
Shutdown*
Power Structure Enabled = 1 Aborting
Major Faulted
Disable*
Power Structure Enabled = 1 Aborting
Major Faulted
Start Inhibit*
Power Structure Enabled = 1 Aborting
Major Faulted
Fault Reset
Shutdown = 1
Shutdown
Major Faulted
Fault Reset
Shutdown = 0
DC Bus Up = 0
Pre-Charge
Major Faulted
Fault Reset
Shutdown = 0
DC Bus Up = 1
Start Inhibit > 0
Start Inhibited
Major Faulted
Fault Reset
Shutdown = 0
DC Bus Up = 1
Start Inhibit =0
Stopped
Major Faulted
Reconnection
Initializing
Stopped
Shutdown*
Power Structure Enabled = 1 Stopping
Stopped
Disable*
Power Structure Enabled = 1 Stopping
Stopped
Start Inhibit*
Power Structure Enabled = 1 Stopping
Stopped
Start Inhibit
Power Structure Enabled = 0 Start Inhibit
Stopped
Not Bus Up
Pre-Charge
Stopped
Shutdown
Shutdown
Stopped
Major Fault
Major Faulted
Stopped
Enable
Starting
Stopped
Test (Active)
Starting
Starting
Shutdown
Shutdown
Starting
Major Fault
Aborting