Behavior models used in CIP Motion
Chapter 2
Rockwell Automation Publication MOTION-RM003I-EN-P - February 2018
55
Tip:
*Specific Standby state after a fault reset is determined by applying Fault Reset State
Transition Precedence rules.
Valid transitions for the Axis State Model of a Feedback Only axis or CIP Motion
Encoder are defined in the following table:
Current State
Event
Conditions
Next State
Off
Power Up
Self Test
Initializing
Initialization Fault
Major Faulted
Initializing
Initialization Complete
Start Inhibited
Shutdown
Major Fault
Major Faulted
Shutdown
Shutdown Reset
Running
Start Inhibited
Shutdown
Shutdown
Start Inhibited
Major Fault
Major Faulted
Start Inhibited
Inhibits Cleared
Running
Major Faulted
Fault Reset
Shutdown = 1
Shutdown
Major Faulted
Fault Reset
Shutdown = 0
Start Inhibited > 0
Start Inhibited
Major Faulted
Fault Reset
Shutdown = 0
Start Inhibited = 0
Running
Major Faulted
Reconnection
Initializing
Running
Shutdown
Shutdown
Running
Major Fault
Major Faulted
Any State
Connection Close
Initializing
Any State
Connection Loss
Major Faulted