Chapter 4
CIP Axis Attributes
396
Rockwell Automation Publication MOTION-RM003I-EN-P - February 2018
Motor Winding to Ambient Resistance
Usage
Access
Data Type Default
Min
Max
Semantics of Values
Optional
Set/GSV
REAL
0
DB
0
°C/Watt
The Motor Winding to Ambient Thermal Resistance attribute is a floating point
value that specifies the winding-to-ambient thermal resistance.
See also
Load Transmission and Actuator Attributes
These are the motor configuration attributes that apply to Permanent Magnet
motor types in general.
PM Motor Resistance
Usage
Access
Data Type Default
Min
Max
Semantics of Values
Required
Set/SSV*
REAL
0
DB
0
-
Ohms
*
Indicates the attribute cannot be set while the drive power structure is enabled (Power Structure Enable bit in CIP Axis Status
is true).
The PM Motor Resistance attribute is a floating point value that specifies the
phase-to-phase, resistance of a permanent magnet motor.
PM Motor Inductance
Usage
Access
Data Type Default
Min
Max
Semantics of Values
Required
(SPM Only)
Set/SSV*
REAL
0
DB
0
-
Henries
*
Indicates the attribute cannot be set while the drive power structure is enabled (Power Structure Enable bit in CIP Axis Status
is true).
The PM Motor Inductance attribute is a floating point value that specifies the
phase-to-phase, inductance of a permanent magnet motor.
General Permanent Magnet
Motor Attributes