CIP Axis Attributes
Chapter 4
Rockwell Automation Publication MOTION-RM003I-EN-P - February 2018
401
Rotary Motor Fan Cooling Speed
Usage
Access
Data
Type
Default
Min
Max
Semantics of Values
Optional
Set/GSV
REAL
0
0
RPM
The Rotary Motor Fan Cooling Speed attribute selects the output speed of the
motor below which the Motor Rated Continuous Current is derated due to the
reduced effectiveness of an integral fan cooling system.
Rotary Motor Fan Cooling Derating
Usage
Access
Data
Type
Default
Min
Max
Semantics of Values
Optional
Set/GSV
REAL
0
0
% Motor Rated
The Rotary Motor Fan Cooling Derating attribute selects the % derating of the
motor when the motor is operating at a speed below the specified Motor Fan
Cooling Speed. A value of 70% would indicate that the motor can only run at 70%
rated continuous current when operating below the Motor Fan Cooling Speed.
See also
General Permanent Magnet Motor Attributes
General Linear Motor Attributes
These are the motor configuration attributes that apply specifically to induction
motor types.
Induction Motor Rated Frequency
Usage
Access
Data
Type
Default
Min
Max
Semantics of Values
Required - D
Set/GSV
REAL
60
DB
0
Hertz
The Induction Motor Rated Frequency attribute is a floating point value that
specifies the nameplate frequency rating of an induction motor.
Induction Motor Attributes