Installation
GasEye Cross Duct
Operating instructions, 05/2021
27
3. Put M16 screws through flange and mount it on the process flange with
another graphite gasket between flange and purging tube.
Figure 14. M16 screws mounting.
4. Screw on M16 nuts with pads and tighten them with 14mm hex key and
24mm wrench. Nuts should be tightened with similar torque (around 60-
70Nm) to ensure good sealing on the gaskets.