5 Calibration, M2000
5.3.8 Resetting of Levelmeter 2000 and sensor
126
3HAC021111-001 Revision: B
Result
The Levelmeter 2000 and the one sensor is now reset and ready for service. When moving
the sensor and the sensor plate to different axes, move it as a complete unit.
6.
Clean the sensor plate attachment area on the
fixture with isopropanol.
7.
Fit the sensor unit (sensor plate and sensor) on
to the sensor fixture and connect the sensor to
the Levelmeter 2000.
Correct direction is shown in
Positions and directions of sen-
sor on page 106.
Connection is shown in the fig-
ure Sensor mounted on fixture
on page 124.
8.
Press ON/MODE on the Levelmeter 2000 until
the dot flashes under REL ZERO .
Shown in the figure Levelmeter
2000 on page 124!
9.
Press ENTER.
10.
Wait until + or - flashes.
11.
Press HOLD .
12.
Wait until + or - flashes.
13.
Press ENTER.
Step
Action
Info/Illustration
Summary of Contents for IRB 1400
Page 1: ...Product manual Articulated robot IRB 1400 M2004 ...
Page 2: ......
Page 3: ...Product manual 3HAC021111 001 Revision B Articulated robot IRB 1400 M2000 M2004 ...
Page 12: ...0 0 2 Product documentation M2000 10 3HAC021111 001 Revision B ...
Page 132: ...5 Calibration M2000 5 4 1 Post calibration procedure 130 3HAC021111 001 Revision B ...
Page 142: ......
Page 148: ...7 Alternative calibration 7 0 5 Retrieving offset values 146 3HAC021111 001 Revision B ...
Page 170: ...10 Foldouts 10 0 1 Introduction 168 3HAC021111 001 Revision B ...
Page 171: ......
Page 172: ......
Page 173: ......
Page 174: ......
Page 175: ......
Page 176: ......
Page 177: ......
Page 178: ......
Page 179: ......
Page 180: ......
Page 182: ...11 Circuit diagram 11 0 1 Introduction 170 3HAC021111 001 Revision B ...
Page 196: ...Index 184 ...
Page 197: ......