5 Calibration, M2000
5.3.5 Calibration, axis 5
118
3HAC021111-001 Revision: B
5.3.5 Calibration, axis 5
General
This section details how to perform the actual fine calibration of axis 5 using the Wyler cali-
bration equipment.
Required
equipment
TIP!
Lock the axes previous to the one calibrated to minimize the risk of accidentally moving other
axes! In case of accidental movement of previous axes, the calibration procedure must be
restarted from the moved axis and continued in increasing sequence!
Procedure
Equipment
Art. no.
Info
Levelmeter 2000 cali-
bration kit with one sen-
sor
6369 901-347
Sensor plate
3HAC 0392-1
One sensor plate is required for each sensor.
Turning disk fixture
6808 0011-GU
For fitting the calibration sensor plate to the sync
adapter.
Isopropanol
1177 1012-108
For cleaning the attachment points.
Other tools and proce-
dures may be required.
See references to these
procedures in the step-
by-step instructions
below.
These procedures include references to the
tools required.
Step
Action
Illustration
1.
Clean the manipulator turning disk with isopropanol . Art. no. is specified in
Required equipment on
page 118!
2.
Fit the sync adapter to the turning disk.
Fit the turning disk fixture (incl. pin) on the turning
disk.
Art. no. is specified in
Required equipment on
page 118!
3.
Turn the tool clockwise against the pin at the same
time as the screws are tightened.
4.
Run the program \SYSTEM\UTILITY\SER-
VICE\CALIBRAT\CALxxxx (xxxx=robot model, e.g.
7600) in the system and select Calib: CAL5.
The robot will now move to the position for calibration
of axis 5.
5.
Reset the levelmeter with correct orientation of the
sensor for calibration of axis 5.
Detailed in section Reset-
ting of Levelmeter 2000 and
sensor on page 124.
Summary of Contents for IRB 1400
Page 1: ...Product manual Articulated robot IRB 1400 M2004 ...
Page 2: ......
Page 3: ...Product manual 3HAC021111 001 Revision B Articulated robot IRB 1400 M2000 M2004 ...
Page 12: ...0 0 2 Product documentation M2000 10 3HAC021111 001 Revision B ...
Page 132: ...5 Calibration M2000 5 4 1 Post calibration procedure 130 3HAC021111 001 Revision B ...
Page 142: ......
Page 148: ...7 Alternative calibration 7 0 5 Retrieving offset values 146 3HAC021111 001 Revision B ...
Page 170: ...10 Foldouts 10 0 1 Introduction 168 3HAC021111 001 Revision B ...
Page 171: ......
Page 172: ......
Page 173: ......
Page 174: ......
Page 175: ......
Page 176: ......
Page 177: ......
Page 178: ......
Page 179: ......
Page 180: ......
Page 182: ...11 Circuit diagram 11 0 1 Introduction 170 3HAC021111 001 Revision B ...
Page 196: ...Index 184 ...
Page 197: ......