![ABB Ability 800xA Series Operation Download Page 98](http://html.mh-extra.com/html/abb/ability-800xa-series/ability-800xa-series_operation_2371098.webp)
Changing Recipe Values
Section 4 TCL Displays
98
3BUR002418-600 A
Changing Recipe Values
Only recipe values can be changed from the Recipe Detail Display. To edit a recipe
value, select the parameter you want to change, type a new value and press Enter.
TCL Array Plot Display
There are two primary ways plot display are configured: the Plot and the Filled Plot.
The Plot display shows data contained in a TCL array as a contiguous trace. As
many as two traces of data can be plotted at one time. The Filled Plot configuration,
, is a single trace, filled with a color between the x-axis and the trace line.
TCL Array Plot Format
Plot displays require a TCL floating point array to store the configuration attributes
and plot point values. The array must be large enough to store values for all the
points to be plotted.
Plots and filled plots can have vertical blue lines drawn at user-specified locations.
Plots of this type are called Hybrid Plots. Hybrid plot displays are useful for flat
sheet applications. A TCL hybrid line array is required for the hybrid plot display.
The hybrid line array is a TCL real number array that is 260 elements long.
Using TCL Array Plot
When using the
In Plot Array
option, the first 10 elements of the array are used as
the plot display's attribute values. All other elements of the array may contain the
plot point values. The points are drawn on the array plot display consecutively from
left to right. Therefore, it is important that you enter the values for the plot points in
the proper elements of the array.
Any changes to recipe values from the Recipe Detail Display are not permanent.
The changes are temporary and only apply to the current batch.
The plot array may give you an inaccessible error on first use. Also, anything that
causes a disconnect with the Connectivity Server will cause error values. Upon
reconnect, inaccessible errors will occur.
Summary of Contents for Ability 800xA Series
Page 1: ...Power and productivity for a better worldTM 800xA for MOD 300 Operation System Version 6 0 ...
Page 2: ......
Page 3: ...800xA for MOD 300 Operation System Version 6 0 ...
Page 14: ...Table of Contents 14 3BUR002418 600 A ...
Page 74: ...Area Graphic Display Section 3 CCF Displays 74 3BUR002418 600 A ...
Page 102: ...Batch Connectivity to M0D 300 Section 4 TCL Displays 102 3BUR002418 600 A ...
Page 120: ...TLL Messages Section 5 TLL Displays 120 3BUR002418 600 A ...
Page 212: ...Viewing Abnormal State on MOD Loop Displays Section 8 Operation Examples 212 3BUR002418 600 A ...
Page 320: ...BRKPTS Appendix A Runtime Templates 320 3BUR002418 600 A ...
Page 322: ...Updates in Revision Index A 322 3BUR002418 600 A ...
Page 330: ...Index 330 3BUR002418 600 A ...
Page 331: ......