9.4 Displaying
Latency Test Results
Procedure
Latency Test Results Screen
Follow the procedure in section 9.1 to start and stop measurement.
Press the
Latency
soft key to display the following screen.
Switches the graph display
Latency test results graph
Latency test results table
Note
• You can display this screen even during measurement.
• You can also use the left and right arrow keys to switch between measurement screens. For details, see
section 9.8.
• Press ESC to return to the Test Result Display screen (see section 9.2).
Explanation
Latency Test Results Graph
The measured results are displayed on a graph.
• Horizontal axis: Test frame length
• Vertical axis:
Delay (μs). You can switch the units that the graph is displayed in between store
and forward (Store&Forward) and cut through (Cut Through).
Latency Test Results Table
The following items are displayed.
• No: This is the test frame length number. If pass/fail judgment is enabled, the pass/fail
judgment results are indicated with colors for each frame length.
Green: Pass
Red: Fail
• Length: Test frame length
• TestRate(%): Test rate (%)
• S&F(us): The measured result under the store and forward system is displayed.
• CT(us): The measured result under the cut through system is displayed.