7-8
IM AQ1300-01EN
7.2 Performing
L1 Control
Procedure
L1 control is valid when Test Interface is set to XFP(10GbE) or SFP(GbE).
Press the
Special Control
soft key and then the
L1 Control
soft key to display the following screen.
Executes or releases Laser OFF
Starts or stops LF transmission
Starts or stops RF transmission
Example when Test Interface Is Set to XFP(10GbE)
These settings are valid when Test
Interface is set to XFP(10GbE).
Changes the transmission frequency
Explanation
Laser OFF Execution and Release
• Laser OFF Execution: When you press the Laser OFF Execution soft key, it changes to the
Laser OFF Release soft key, and the laser is turned off.
• Laser OFF Release:
When you press the Laser OFF Release soft key, it changes to the Laser
OFF Execution soft key, and the laser is turned on.
Send LF Start and Stop
• Send LF Start:
When you press the Send LF Start soft key, it changes to the Send LF
Stop soft key, and LFs are sent.
• Send LF Stop:
When you press the Send LF Stop soft key, it changes to the Send LF
Start soft key, and LF transmission is stopped.
Send RF Start and Stop
• Send RF Start:
When you press the Send RF Start soft key, it changes to the Send RF
Stop soft key, and RFs are sent.
• Send RF Stop:
When you press the Send RF Stop soft key, it changes to the Send RF
Start soft key, and RF transmission is stopped.
Note
• You can perform L1 control regardless of whether transmission is in progress or stopped.
• Send LF and RF Start and Stop are valid when Test Interface is set to XFP(10GbE).
• LF and RF transmission are exclusive. If you start LF transmission during RF transmission, RF
transmission will stop. If you start RF transmission during LF transmission, LF transmission will stop.