7-14
IM AQ1300-01EN
7.6 Displaying
Test Results
Procedure
Follow the procedure in section 7.1 to start or stop measurement.
Press the
Test Result Display
soft key to display the following screen.
Switches the rate unit (%, fps, bps)
This setting is valid when you are
performing a traffic or QoS test.
Switches the contents of the summary
display (Summary, Address)
Switches the traffic indication
(Maximum, Average)
This setting is valid when you are
performing a traffic test.
Switches the QoS indication
(Maximum, Average, Current)
This setting is valid when you are
performing a QoS test.
Example When a Traffic Test Is Being Performed
Explanation
Rate Unit
This soft key switches the unit of the measured rate. This setting is valid when you are performing a
traffic or QoS test.
• %: The rate is displayed as a percentage.
• fps: The number of frames that have been received normally in a single second is indicated.
• bps: The number of bits that have been received normally in a single second is indicated.
Traffic
This soft key switches between the types of values that are displayed for the Rx rate and the packet
latency. This soft key is valid when you are performing a traffic test.
• Maximum: The maximum values are indicated.
• Average: The average values are indicated.
QoS
This soft key switches the types of values that are displayed for the Rx QoS channel rates. This
setting is valid when you are performing a QoS test.
• Maximum: The maximum values are indicated.
• Average: The average values are indicated.
• Current: The current values are indicated.
Summary display
You can switch the contents of the summary display.
• Summary: A summary of the settings is displayed.
Test Mode
Displayed Items
Traffic Test
Tx rate, Tx time, frame length, fill pattern
Loopback Test
Loopback target
QoS Test
Tx rate for each channel
PING Test
Destination IP address, Tx interval, number of frames
BERT
Tx rate, Tx time, frame length
• Address: The source and destination MAC and IP addresses are displayed.
Note
You can change the contents of the Test Result Display regardless of whether measurement is in progress or
stopped.