6-27
IM AQ1300-01EN
Manual T
est Settings (Manual)
3
2
1
4
5
6
7
8
9
10
11
12
13
14
15
16
App
Index
Target Frame Setting
Set which frames to take statistics of.
• Test Frame Only: Statistics are only taken for test frames.
• All Frames:
Statistics are taken for all frames.
Rx Base Filter Setting
Frame Structure
The specified frame structure is displayed.
Note
The AQ1300/AQ1301 will receive the type of frames specified by the Frame Structure setting.
Detail
Press to configure the Rx frame settings in the Frame Setting screen.
Filter 1 and 2
Specify the Rx base filters that you want to use.
• Selected: The Rx base filter is used.
• Cleared: The Rx base filter is not used.
The selected Rx base filter type is displayed.
Detail
Press to configure the Rx base filter settings in the Rx Base Filter Setting screen.
Combination
Set the combination condition for Rx base filters 1 and 2.
• AND: The conditions of the Rx base filters are combined using AND logic.
• OR: The conditions of the Rx base filters are combined using OR logic.
Condition
Select the type of frame to allow to pass through the Rx base filters. The AQ1300/AQ1301 takes the
statistics of the frames that pass through the filters.
• Match: Frames that match the filter conditions pass through the filters.
• Mismatch: Frames that do not match the filter conditions pass through the filters.
Frame Setting Screen
Frame Structure, Refer to Source Address for the VLAN Setting, and VLAN Stacks
These settings are the same as the settings in the Frame Setting (Basic setting) screen. For details,
see the Frame Setting (basic setting) screen.
Rx Base Filter Setting Screen
Method
Set the Rx base filter method.
• Field: Specify a field.
• Offset: Specify an offset.
Field
Set the Rx base filter when Type is set to Field.
The settings that you can specify are the same as the ones that you can specify in the Variable
Field Setting screen. For details, see the Variable Field Setting screen.
6.5 Configuring a Traffic Test