7.4 Inserting
Errors
Procedure
Follow the procedure in section 7.1 to start measurement and transmission for a traffic, QoS, or BER
test.
Press the
Special Control
soft key and then the
Error Insertion
soft key to display the following
screen.
Example When a BERT Is Being Performed
Inserts a bit error
Valid when the test mode is BERT
Inserts a payload error
Inserts a CRC error
Inserts a symbol error
Inserts a sequence error
Explanation
Bit Error
A single bit error is inserted. This soft key is valid during a BER test.
CRC Error
A single frame is inserted with a CRC error. This setting is valid when you are performing a traffic,
QoS, or BER test.
Symbol Error
A single frame is inserted with a symbol error. This setting is valid when you are performing a traffic,
QoS, or BER test.
Sequence Error
A single frame is inserted with a sequence error. This setting is valid when you are performing a
traffic, QoS, or BER test.
Payload Error
A single frame is inserted with a payload error. This setting is valid when you are performing a
traffic, QoS, or BER test.
Note
When Manual has been selected in the Test menu, if you select the “Remove Test Tag from Test Frame”