6-7
IM AQ1300-01EN
Manual T
est Settings (Manual)
3
2
1
4
5
6
7
8
9
10
11
12
13
14
15
16
App
Index
Continuing to Transmit while the Link Is Down
When Test Interface is set to XFP(10GbE), you can specify whether to continue or stop transmission
after a linkdown is detected.
• Selected: Transmission continues when a linkdown is detected.
• Cleared: Transmission stops when a linkdown is detected.
Tx Clock Source Setting
Specify the Tx clock source for when Test Interface is set to XFP(10GbE) or SFP(GbE).
When Test Interface is set to SFP(FE) or RJ-45, the Tx clock source is fixed to the internal clock.
• Internal CLK:
The internal clock is used.
• Received CLK: The AQ1300/AQ1301 synchronizes with the Rx line signal.
When Test Mode is set to Loopback Test, if Test Interface is set to XFP(GbE) or SFP(GbE), the
AQ1300/AQ1301 uses the received clock regardless of the Tx clock source setting.
Link Setting Acquisition
If the interface is SFP(GbE) or RJ-45, you can acquire and display link setting information of the
other device (DUT; the device on the user side) connected to the AQ1300/AQ1301. For details, see
section 4.3.
Source Address Screen
Source MAC Address
Set the source MAC address. You can refer to the MAC Address table to set the address.
VLAN Stacks
Set the number of VLAN stacks.
• None: No VLAN stacks.
• 1: One VLAN stack.
• 2: Two VLAN stacks.
VLAN1 and VLAN2
Set the TPID (Tag Protocol Identifier), CFI (Canonical Format Indicator), CoS (Class of Service),
and VLAN-ID for when there are one or two VLAN stacks. You can refer to the VLAN table to set
the values.
• TPID: 0 to FFFF
• CFI: 0 or 1
• CoS: 0 to 7
• ID: 0 to 4095
IPv4
Select whether to specify the source IPv4 address manually or to acquire and set it automatically
through DHCP. This setting is valid when Test Layer is set to L3-IPv4 Test.
• Manual: You must set the source IPv4 address manually.
• DHCP: When you press Get IP Address, the AQ1300/AQ1301 acquires and sets the source
IPv4 address using DHCP.
Source IPv4 Address, Subnet Mask, and Gateway
Set the source IPv4 address, subnet mask, and gateway when IPv4 is set to Manual. You can refer
to the IP Address table and the gateway reference to configure the settings.
• Subnet Mask: 1 to 31
IPv6
Select whether to specify the source IPv6 address manually or to specify it through stateless
autoconfiguration using the RA from an IPv6 router. This setting is valid when Test Layer is set to
L3-IPv6 Test.
• Manual:
You must set the source IPv6 address manually.
• Stateless Address:
When you press Get IP Address, the AQ1300/AQ1301 autoconfigures
the source IPv6 address.
6.3 Configuring Link and Address Settings