![YASKAWA U1000 iQpump Drive Скачать руководство пользователя страница 589](http://html1.mh-extra.com/html/yaskawa/u1000-iqpump-drive/u1000-iqpump-drive_technical-manual_3309131589.webp)
No.
Name
Unit
Default Settings
–
Drive Model
–
2
o
0081
2
o
0104
2
o
0130
2
o
0154
C6-01
Drive Duty Selection
–
HD
ND
HD
ND
HD
ND
HD
ND
o2-04
Drive Model Selection
Hex.
6F
70
72
73
E2-11
(E4-11)
Motor Rated Output
kW
(HP) 18.5 (25) 22 (30)
22 (30)
30 (40)
30 (40)
37 (50)
37 (50)
45 (60)
E2-03 (E4-03) Motor No-Load Current
A
15.7
18.5
18.5
21.9
21.9
38.2
38.2
44
E2-05 (E4-05) Motor Line-to-Line Resistance
Ω
0.101
0.079
0.079
0.064
0.064
0.039
0.039
0.03
E2-06 (E4-06) Motor Leakage Inductance
%
20.1
19.5
19.5
20.8
20.8
18.8
18.8
20.2
E2-10 (E4-10) Motor Iron Loss for Torque Compensation
W
505
538
538
699
699
823
823
852
E5-01
Motor Code Selection (for PM Motors)
Hex.
120F
120F
1210
1210
1212
1212
1213
1213
L2-02
Momentary Power Loss Ride-Thru Time
s
1
1
1
1.1
1.1
1.1
1.1
1.2
L2-03
Momentary Power Loss Minimum
Baseblock Time
s
0.6
0.6
0.6
0.6
0.6
0.6
0.6
1
L2-04
Momentary Power Loss Voltage Recovery
Time
s
150
150
150
150
150
150
150
150
L2-21
Low Input Voltage Detection Level
V
150
150
150
150
150
150
150
150
L8-02
Overheat Alarm Level
°C
130
130
130
130
130
130
130
130
L8-35
Installation Method Selection
–
0
0
0
0
0
0
0
0
L8-38
Carrier Frequency Reduction Selection
–
1
1
1
1
1
1
1
1
n1-03
Hunting Prevention Time Constant
ms
10
10
10
10
10
10
10
10
n5-02
Motor Acceleration Time
s
0.317
0.355
0.355
0.323
0.323
0.32
0.32
0.387
Table B.11 200 V Class Drives Default Settings by Drive Model Selection and ND/HD Settings
No.
Name
Unit
Default Settings
–
Drive Model
–
2
o
0192
2
o
0248
C6-01
Drive Duty Selection
–
HD
ND
HD
ND
o2-04
Drive Model Selection
Hex.
74
75
E2-11 (E4-11)
Motor Rated Output
kW (HP)
45 (60)
55 (75)
55 (75)
75 (100)
b3-04
V/f Gain during Speed Search
%
80
80
80
80
b3-06
Output Current 1 during Speed Search
–
0.5
0.5
0.5
0.7
b3-08
Current Control Gain during Speed Search
(Speed Estimation Type)
–
0.5
0.5
0.5
0.5
b8-03
Energy Saving Control Filter Time Constant
s
0.50
2.00
2.00
2.00
b8-04
Energy Saving Coefficient Value
–
35.78
31.35
31.35
23.1
C5-17 (C5-37)
Motor Inertia
kgm
2
0.333
0.490
0.490
0.900
C6-02
Carrier Frequency Selection
–
1
1
1
1
E2-01 (E4-01)
Motor Rated Current
A
160
190
190
260
E2-02 (E4-02)
Motor Rated Slip
Hz
1.6
1.43
1.43
1.39
E2-03 (E4-03)
Motor No-Load Current
A
44
45.6
45.6
72
E2-05 (E4-05)
Motor Line-to-Line Resistance
Ω
0.03
0.022
0.022
0.023
E2-06 (E4-06)
Motor Leakage Inductance
%
20.2
20.5
20.5
20
E2-10 (E4-10)
Motor Iron Loss for Torque Compensation
W
852
960
960
1200
E5-01
Motor Code Selection (for PM Motors)
Hex.
1214
1214
1215
1215
L2-02
Momentary Power Loss Ride-Thru Time
s
1.2
1.3
1.3
1.5
L2-03
Momentary Power Loss Minimum Baseblock Time
s
1
1
1
1
L2-04
Momentary Power Loss Voltage Recovery Time
s
150
150
150
150
L2-21
Low Input Voltage Detection Level
V
150
150
150
150
L8-02
Overheat Alarm Level
°C
130
130
130
130
L8-35
Installation Method Selection
–
0
0
0
0
L8-38
Carrier Frequency Reduction Selection
–
1
1
1
1
n1-03
Hunting Prevention Time Constant
ms
10
10
10
10
n5-02
Motor Acceleration Time
s
0.387
0.317
0.317
0.533