n
Tools Required for Installation
A straight-edge screwdriver (blade depth: 0.4 mm, width: 2.5 mm) is required to install the unit and wire the option terminal
block.
Note:
Tools required to prepare option cables for wiring are not listed in this manual.
n
Power Supply Terminal Block TB1 Functions
Figure 3.58 Power Supply Terminal Block TB1
Table 3.25 Power Supply Terminal Block TB1 Functions
Terminal
Function
24
+24 Vdc Input
0
0 V
FE
Ground
n
Wire Gauges and Tightening Torques
Table 3.26 Wire Gauges and Tightening Torques
Terminal
Screw Size
Tightening
Torque N
•
m
(in
•
lb)
Bare Cable
Crimp Terminals
Wire Type
Recomm.
Gauge mm
2
(AWG)
Applicable
Gauges mm
2
(AWG)
Recomm.
Gauge mm
2
(AWG)
Applicable
Gauges mm
2
(AWG)
24, 0, FE
M2
0.22 to 0.25
(1.95 to 2.21)
0.75 (18 AWG)
Stranded wire:
0.25 to 1.0
(24 to 17 AWG)
Solid wire:
0.25 to 1.5
(24 to 16 AWG)
0.5 (20 AWG)
0.25 to 0.5
(24 to 20 AWG)
Shielded twisted
pair, etc.
n
Ferrule-Type Wire Terminals
Yaskawa recommends using CRIMPFOX 6, a crimping tool manufactured by PHOENIX CONTACT, to prepare wire ends
d1
d2
6 mm
L
(0.24 in.)
Figure 3.59 Ferrule Dimensions
Table 3.27 Ferrule Terminal Types and Sizes
Size mm
2
(AWG)
Type
L mm (in)
d1 mm (in)
d2 mm (in)
Manufacturer
0.25 (24)
AI 0.25-6YE
AI 0.25-6BU
10.5 (0.41)
0.8 (0.03)
2.0 (0.08)
PHOENIX CONTACT
0.34 (22)
AI 0.34-6TQ
10.5 (0.41)
0.8 (0.03)
2.0 (0.08)
0.5 (20)
AI 0.5-6WH
12 (0.47)
1.1 (0.04)
2.5 (0.10)