![YASKAWA U1000 iQpump Drive Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/yaskawa/u1000-iqpump-drive/u1000-iqpump-drive_technical-manual_3309131032.webp)
Motor Type
Induction Motors
Permanent Magnet Motors
Comments
Control Mode
V/f
V/f w/PG
OLV
CLV
OLV/PM
AOLV/PM
CLV/PM
–
Type of
Applications
Motor Type
IM
IM
IM
IM
PM
IPM
PM
–
Multi Motor
YES
–
–
–
–
–
–
–
Motor data
unknown
YES
–
–
–
–
–
–
–
High Speed
Accuracy
–
YES
YES
YES
YES
YES
YES
–
High Speed
Response
–
–
YES
YES
–
YES
YES
–
Zero Speed
Control
–
–
–
YES
–
YES
YES
–
Torque Control
Operation
–
–
–
YES
–
–
YES
–
Torque Limit
Operation
–
–
YES
YES
–
–
YES
–
PG Option Card
–
PG-B3 or
PG-X3
–
PG-B3 or
PG-X3
–
–
PG-X3
–
Control
Characteristics
Speed Control
Range
1:40
1:40
1:200
1:1500
1:20
1:20
1:100
1:1500
May fluctuate with
characteristics and
motor temperature.
May fluctuate with
characteristics and
motor temperature.
Enabled for 1:100
when n8-57, High
Frequency Injection,
is set to 1 (Enabled).
Speed Accuracy
±2 to 3%
±0.03%
±0.2%
±0.02%
±0.2%
±0.2%
±0.02%
Speed deviation rate
between speed
reference value and
motor speed (100%
= rated speed, motor
temperature 25 °C
±10 °C) when
operating at normal
status and when load
is stable.
Speed Response
3 Hz (approx.) 3 Hz (approx.)
10 Hz
50 Hz
10 Hz
10 Hz
50 Hz
Max. frequency of a
speed reference
signal that the drive
can follow may
fluctuate with
characteristics and
motor temperature.
Starting Torque
150% at 3 Hz
150% at 3 Hz
200% at
0.3 Hz
200% at
0 r/min
100% at
5% speed
100% at 5%
speed
200% at 0 r/min
200% at
0 r/min
Starting torque may
fluctuate with
characteristics and
motor temperature.
Performance may
differ by capacity.
200% at 0 r/min
enabled when n8-57,
High Frequency
Injection, is set to 1
(Enabled).
1.2 General Description
32
YASKAWA ELECTRIC SIEP C710636 04D U1000 Industrial MATRIX Drive Technical Manual
Содержание U1000 iQpump Drive
Страница 705: ......