~Note
Output configurations for ISO mode are given for each item.
(Ex. “SCV (real)” at PV12)
The items above that are circled cannot be selected when calculation mode
is GPA. However, these items can be viewed in the GPA mode. The circled
items can be selected in ISO mode. If you want to change to ISO mode,
refer to “3-3-4 : Set up HGM” on page 3-15.
(3) Reference conditions
Configuration data for heat value calculation can be either selected from the menu or
input manually.
(3-1) C6+ configuration
Select a value to be used as C6+'s physical constant.
• 47/35/17 [Default]
• 50/50/0
• 50/25/25
• 57/28/14
• Other value
~Note
If [Other value] is selected, the following screen will appear.
Input each value for C6+'s physical constant.