Use the following check list to troubleshoot your network communication problem.
Check Physical Media and Network Interface Cards
1.
Verify that the Device is powered ON.
2.
Verify that the Device and Workstation are using the correct cabling to communicate over the network.
Use category 3 UTP patch (NOT crossover) cable for 10 Base T communications, category 5 UTP
patch (NOT crossover) cable for 10 Base T / 100 Base TX communications, and Token Ring cabling
for Token Ring networks.
3.
Verify that the cable at both the Device and Workstation is fully plugged into the Network Interface
Card (NIC). Check the link light, which is typically a green LED, to make sure that it is lit. Typically, but
not always, a second light on the Network Interface Card will be intermittently flashing, indicating the
presence of network traffic. If neither of these lights is lit, there is a problem with the NIC.
Print a Configuration Report at the Device and perform these tasks:
1.
Under the
Ethernet Rated Speed
data label on the Report, verify that your communications speed is
correctly set for your network and that you have a MAC address listed. The driver for your NIC works
at the Media Access Control (MAC) layer of the protocol stack. If no MAC address is shown, you have
either a bad NIC or no NIC at all. Replace or install the Network Interface Card.
2.
Under the
CentreWare Internet Services
data label, verify that this feature is Enabled. If it is NOT,
enable it following the instructions supplied in the
Network Connectivity
section of this guide.
3.
Under the
TCP/IP
data label, determine the method being used to assign TCP/IP addressing to the
Device. Verify that the IP Address, Subnet Mask, and Gateway addresses are correct for your network
and have NOT changed from their previous settings. Note: The use of DHCP (the DHCP Server) with
a short "lease" time can cause the Device to be assigned a new IP Address when it is powered off for
an extended period of time. This will interrupt communications with workstations using the "old" IP
address. If you do not want the IP address to be subject to constant changes, either increase the
lease time at the DHCP Server, or use the Static IP Addressing method as described in the
TCP/IP
Protocol Configuration
procedure in the NOS selection section of this guide.
4.
Under the
IPP
data label, verify that the IPP Port is Enabled. If it is NOT, enable the port following the
procedure stated in the
IPP Configuration
topic in the NOS Selection section of this guide.
5.
Under the
IPP
data label, verify that IPP is using
DNS
to resolve Host Names to IP Addresses in
support of IPP printing. If it is NOT, using your workstation's Web browser enter the TCP/IP Address
of the Device in the Address or Location field. Press
Enter
. Click the
Properties
tab. Click the plus
(+) symbol to the left of
Connectivity
, then the
Protocols
file folder and
select IPP
in the directory
tree. Verify that the DNS Enablement Checkbox is checked. If it is NOT checked, check it with your
mouse and click
Apply
. Reboot the Device with the
Reboot Machine
button on the Status tab.
6.
Under the
IPP
data label, verify that the Port number associated with IPP is
631
. This is the port
number assigned to IPP by the Internet Assigned Numbers Authority. If the number is not 631, set it to
631 following the instructions supplied in the
Configure IPP
procedure in the Internet Services section
of this guide.
Содержание WorkCentre 7300 Series
Страница 1: ...System Administrator s Guide 701P47983 WorkCentre 7300 Series ...
Страница 12: ...x ...
Страница 203: ......