Setting the Auto Clear Timer
For security purposes, the Auto Clear service will automatically log the System Administrator out of the
machine’s
Tools
tab, after a period of inactivity determined by the Auto Clear timer.
To set the Auto Clear Timer to a duration of up to 240 seconds, perform the following steps.
1.
Press the
Log In / Out button
on the Device’s Control Panel.
2.
Press the
"1"
key on the numeric keypad five consecutive times. This is the factory default
"password."
3.
Press
Enter
on the touch screen.
4.
Press the
Machine Status button
on the Control Panel.
5.
Press the
Tools tab
.
6.
Press
System Settings
tab.
7.
Press
Common Service Settings
.
8.
Press
Machine Clock/Timers
.
9.
Press
Auto Clear
, then
Change Settings
.
10. Use the displayed control to set the timer duration in a range of 30 to 240 seconds.
11. Press the
Save
button.
12. Press
Close
to return to the Tools tab screen.
13. Wait several seconds and the Auto Clear service should log you out.
Add or Remove All Services Screen Buttons
To Add or Remove All Services Screen Buttons:
1.
Press the [Log In / Out] button to enter System Administration Mode.
2.
Type the administrator password (11111 or current password).
3.
Touch [Enter]
4.
Press the [Machine Status] button on the Control Panel.
5.
Touch the [Tools] tab.
6.
Touch [System Settings].
7.
In the Group column, touch [Common Service Settings].
8.
Touch [Screen / Button Settings].
9.
On the Screen / Button Settings screen, in the Items column, touch [All Services].
10. Touch [Change Settings].
11. To add a service screen button:
a.
Touch a [Not Assigned] service button.
b.
Touch the service to be added as a screen button.
c.
Touch [Save].
The screen refreshes and returns to the All Services screen.
d.
Touch [Save] again.
The screen refreshes and returns to the Screen / Button Settings screen.