SmartPad LCD
™
Page:
61
© 2008 Xantech Corporation
Figure 44 – URC-2 RC68 Macro Trigger Programming
RS232 INPUT TRANSLATOR
The SPLCD Touch Screen Controller has the ability to receive specific Xantech RS232 ASCII strings and
associate them to individual IR Commands or IR Macro Sequences to control any number of IR controlled
devices. This allows a central PC (or other RS232 unit) to control any IR device connected to the SPLCD IR
Bus Output.
NOTE:
For RS232 Communication, a
RS422232 Converter
and
12V DC Power Supply
(Xantech Part #
781ERGPS)
(both sold separately) are required. For RS232 Connections, see
Figure 11
in
Section 2
of this
manual. A
Null Modem cable
may be necessary for communicating with the Component or Device. Check the
manufacturer’s specification to see if this is required.