= #" "%1`bY\" "
System
Cooling
(See p. 6-6)
TRANSFORMER
OVER-TEMPERA-
TURE input was not
active when required
by the control, or the
SCR thermal switch
was tripped.
Defective SCR thermostat.
Replace thermostat.
Customer-supplied device
did not activate the TRANS-
FORMER OVER-TEMPERA-
TURE input when required.
Check device.
Loose/incorrect connections
to input module or in circuit.
Check for proper wiring
Insufficient water flow.
Check the water flow, access
holes, hoses and filters (if
used).
Faulty input module.
Replace module.
Heat Cycle
Limit
(See p. 6-6)
The control reached
the programmed limit
of consecutive weld
cycles where conduc-
tion was detected.
Weld schedule programming
was incorrect.
Lower the number of cycles
where the weld control is firing.
Your application does not need
the Heat Cycle Limit setup
parameter. (To disable this
parameter, set it to 0.)
Faulty weld processor card.
Replace weld processor card.
Weld
Interrupt
(See p. 6-7)
The control entered
No Weld mode while
executing a weld
schedule.
Robot or PLC ladder logic
de-activated the WELD/NO
WELD Input.
Check robot or PLC ladder to
verify that the input is being
held HIGH throughout the weld
schedule. (Use the DEP’s I/O
Status display to monitor the
status of this input.) Also check
the DEP I/O status.
Incorrect or loose wiring to
the input module.
Check for proper I/O designa-
tions. Verify that all wiring
connections are secure.
Faulty input module.
Replace input module.
I/O System
Timeout
(See p. 6-7)
The SLC processor
stopped scanning.
The SLC will stop scanning if
a CPU fault occurs at the SLC
processor.
Clear fault and cycle power.
I/O Update
Timeout
(See p. 6-7)
The weld and SLC
processors detected
a loss of communica-
tions for a specified
amount of time while
executing a weld
schedule.
Bad connectors or improper
seating of the weld processor
or the SLC processor in the
chassis.
Remove power from the rack.
Inspect the SLC and weld
processor connections. Re-seat
and restore power.
Weld processor firmware and
SLC ladder logic are incom-
patible.
Verify compatibility. Correct as
necessary.
Message
Explanation
Possible Cause
Remedy
Содержание MedWeld 3005
Страница 2: ...YY UTGU T UbQd_bµc 7eYTU V_b D 1 bY ...
Страница 84: ...3_ e YSQdY_ c Q T 9 UTGU T UbQd_bµc 7eYTU D 1 bY ...
Страница 110: ...GU T CSXUTe Uc UTGU T UbQd_bµc 7eYTU D 1 bY ...
Страница 126: ...1TfQ SUT C_VdgQbU 6UQdebUc UTGU T UbQd_bµc 7eYTU D 1 bY ...
Страница 144: ...CUde QbQ UdUbc UTGU T UbQd_bµc 7eYTU D 1 bY ...