To determine the nominal C-Factor, first perform a series of
welds. Record the actual C-factor displayed at the
programming device. Calculate the average, and enter that as
the nominal C-factor value.
I/O UPDATE TIMEOUT (MSEC): nnnn (0–9999)
This setup parameter programs the maximum length of time
in which the WTC weld processor and SLC processor can
lose communications while initiating without generating an
I/O TIMEOUT fault.
The following parameter supports operation of the Secondary
Current Interface Board (SCIB):
SEC. CURR COIL MULTIPLIER (X1000): nnnn (0-9999)
Use this setup parameter when monitoring secondary
current as an adjustment to accommodate for secondary
current sensing coils of different sensitivities. Setting this
parameter to 1000 will result in accurate secondary current
readings for coils of 0.477
µ
Hy mutual inductance (150 mV/
kA @ 50 Hz, or 180 mV/kA @ 60 Hz). Setting this parameter
above
1,000 will increase the reading. Setting below 1,000 will
decrease the reading.