=UTGU\T# %?`UbQd_bµc7eYTUD)## "
(!
= #" "%1`bY\" "
)DXOW&RQGLWLRQV
The fault conditions generated by the weld processor may not
always identify the source of the problem. However, they do
provide a starting point to begin searching.
Certain operating conditions are defined as Faults, Alerts,
MAJOR, MINOR or NONE conditions in the setup parameters.
However, the control’s response to the conditions is standard:
When the control detects a fault condition you defined as
MAJOR, it may inhibit welding or inhibit initiation of a new
schedule until the fault condition is cleared. Alert or MINOR
fault conditions serve more as a warning of a potential problem,
or that maintenance may be required. If set to NONE, the control
logs the fact that the condition occurred, but takes no action.
The following table lists each fault described in this chapter in
alphabetical order, with the page where the description appears:
Fault
Page
CONTROL IN NO WELD . . . . . . . . . . . . . . . . . . . . . . . . 8-12
CONTROL STOP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-3
END OF STEPPER . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-3
HEAT CYCLE LIMIT. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-10
HIGH C-FACTOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-9
HIGH CURRENT LIMIT . . . . . . . . . . . . . . . . . . . . . . . . . 8-4
I/O SYSTEM TIMEOUT . . . . . . . . . . . . . . . . . . . . . . . . . 8-10
I/O UPDATE TIMEOUT . . . . . . . . . . . . . . . . . . . . . . . . . 8-10
INITIAL POWER FACTOR OUT OF RANGE . . . . . . . . . 8-6
INSUFFICIENT LINE VOLTAGE . . . . . . . . . . . . . . . . . . 8-7
INVALID SEQUENCE SELECTED . . . . . . . . . . . . . . . . 8-2
ISO CONTACTOR OFF WHEN NEEDED . . . . . . . . . . . 8-8
ISOLATION CONTACTOR NOT ENABLED . . . . . . . . . 8-11
LOW BATTERY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-9
LOW C-FACTOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-9
LOW CURRENT LIMIT. . . . . . . . . . . . . . . . . . . . . . . . . . 8-4
NO ZERO CROSSING SYNC . . . . . . . . . . . . . . . . . . . . 8-9
POWER FACTOR LIMIT . . . . . . . . . . . . . . . . . . . . . . . . 8-6
RETRACT PILOT ERROR . . . . . . . . . . . . . . . . . . . . . . . 8-11
REWELDED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-6
Содержание MedWeld 3005
Страница 2: ...YY UTGU T UbQd_bµc 7eYTU V_b D 1 bY ...
Страница 84: ...3_ e YSQdY_ c Q T 9 UTGU T UbQd_bµc 7eYTU D 1 bY ...
Страница 110: ...GU T CSXUTe Uc UTGU T UbQd_bµc 7eYTU D 1 bY ...
Страница 126: ...1TfQ SUT C_VdgQbU 6UQdebUc UTGU T UbQd_bµc 7eYTU D 1 bY ...
Страница 144: ...CUde QbQ UdUbc UTGU T UbQd_bµc 7eYTU D 1 bY ...