2XWSXW0RGXOH
LED
Symptom
Input State
Probable Cause
Corrective Action
ON
SLC program
indicates that the
output circuit is off,
or the output circuit
will not turn off.
On or
energized.
Output circuit is
damaged.
Verify proper wiring. Try
other circuit; replace
module if necessary.
ON
Output device will
not turn on and the
SLC program
indicates that it is
on.
Off or de-
energized.
Output device is
incompatible.
Check specifications and
sink/source compatibility (if
DC output only).
Incorrect wiring or
open circuit.
Check wiring and common
connections.
Output device is
damaged.
Check wiring, try other
output circuit and replace
module, if necessary.
Low or no voltage
across the load.
Measure the source voltage
and check specifications.
ON
Output device will
not turn off and the
SLC program
indicates that it is
off.
On or
energized
Output device is
incompatible.
Check specifications.
Incorrect wiring.
Check wiring, disconnect
from the SLC and verify
device operation.
Output device is
damaged.
Verify device operation.
Replace device, if needed.
Output circuit is
damaged.
Check wiring. Try the other
output circuit; replace the
module if necessary.
Output circuit off-
state leakage current
may exceed output
device specification.
Check specification. Use
load resistor to bleed off
leakage current.
OFF
SLC program
indicates that the
output circuit is on
or the output circuit
will not turn on.
Off or de-
energized.
Output circuit is
damaged.
Verify proper wiring; try
other circuit. Replace
module if necessary.
Содержание MedWeld 3005
Страница 2: ...YY UTGU T UbQd_bµc 7eYTU V_b D 1 bY ...
Страница 84: ...3_ e YSQdY_ c Q T 9 UTGU T UbQd_bµc 7eYTU D 1 bY ...
Страница 110: ...GU T CSXUTe Uc UTGU T UbQd_bµc 7eYTU D 1 bY ...
Страница 126: ...1TfQ SUT C_VdgQbU 6UQdebUc UTGU T UbQd_bµc 7eYTU D 1 bY ...
Страница 144: ...CUde QbQ UdUbc UTGU T UbQd_bµc 7eYTU D 1 bY ...