AIR-INVERTED
indicates an air-only cylinder, but the
output is turned ON to close the gun.
The following sections detail the retract operation under a variety
of combinations of parameter settings. (The Retract Mode setup
parameter is described on page 6-10.)
,QLWLDWLRQ)URP
5HWUDFW
The processor also provides a function which you can place in a
weld schedule to tell the control to check whether the selected
cylinder is out of retract. Function #89 (VERIFY CYLINDER #n IS
OUT OF RETRACT) will abort the schedule and generate a
RETRACT PILOT fault if the cylinder is NOT out of retract.
>?D5*
Program the RETRACT PILOT fault as an ALERT condition in the
setup parameters, so the operator can place the valve in the partial retract
position and re-initiate the weld schedule.
If this condition is defined as a FAULT, the control will require a fault
reset before it can continue. (An exception is when the Initiation On
Fault setup parameter is set to ALLOW, as described on page 6-10.)
If the weld schedule does NOT contain this function, the control
will allow you to execute a sequence with the gun in the full
retract position.
Air-inverted
Retract Output
full retract
partial retract