= #" "%1`bY\" "
RETRACT MODE:
(LATCHED)
(UNLATCHED)
This parameter tells the control how to react when it receives
the RETRACT input:
•
UNLATCHED tells the control to let the RETRACT output
follow the state of the RETRACT input. (When the input is on,
the output is ON; when the input is off, the output is OFF.)
•
LATCHED tells the control to change the state of the
RETRACT output when the input is briefly turned on and then
off (pulsed).
WARNING!
For safety, the MedWeld 3005 ignores any
changes made to this parameter until you
reset the control (by cycling power).
CYLINDER: (AIR-NORMAL)
(AIR-INVERTED)
This setup parameter defines what type of weld gun cylinder
is being used.
•
AIR-NORMAL—Select this type of cylinder when the
machine uses an air-only cylinder, AND the RETRACT output
is turned OFF to close the gun.
•
AIR-INVERTED—Select this type of gun cylinder when the
machine uses an air-only cylinder, AND the RETRACT output
is turned ON to close the gun.
WARNING!
For safety, the MedWeld 3005 ignores any
changes made to this parameter, until you
reset the control (by cycling power).
HIGH POWER FACTOR LIMIT (%): 99 (10–99)
LOW POWER FACTOR LIMIT (%): 10 (10–99)
These two parameters tell the weld control the range of
acceptable values for power factor. If the power factor
exceeds or falls below these limits, a HIGH or LOW POWER
FACTOR LIMIT fault is generated.
Содержание MedWeld 3005
Страница 2: ...YY UTGU T UbQd_bµc 7eYTU V_b D 1 bY ...
Страница 84: ...3_ e YSQdY_ c Q T 9 UTGU T UbQd_bµc 7eYTU D 1 bY ...
Страница 110: ...GU T CSXUTe Uc UTGU T UbQd_bµc 7eYTU D 1 bY ...
Страница 126: ...1TfQ SUT C_VdgQbU 6UQdebUc UTGU T UbQd_bµc 7eYTU D 1 bY ...
Страница 144: ...CUde QbQ UdUbc UTGU T UbQd_bµc 7eYTU D 1 bY ...