The MedWeld 3005 provides commands for:
•
Assigning a schedule to a stepper,
•
Defining the type of stepper to use (linear or SureWeld),
•
Turning selected outputs on or off and
•
Providing weld current.
Other functions enable
•
Overriding the setup parameters,
•
Controlling the I/O by monitoring inputs and activating
outputs,
•
Regulating weld current to fall within a prescribed range,
and repeat the weld if the current is not within that range,
•
Statistical process control (SPC) functions,
•
Selecting the firing mode (to assure consistent voltage or to
assure constant secondary current) and
•
Pausing in a schedule to wait for certain operating conditions
to become true.
Add or delete functions from this list, or change any of the
numeric values specified in a function. This lets you create a
schedule that meets your application requirements.
The following sections describe the functions available for use in
a weld schedule, including the two-digit function code and the
action each function produces.
The functions are grouped according to their purpose in a weld
schedule, and to aid your understanding their overall interaction.