After setting these values, select
APPLY NODE SETTINGS
.
The card will now re-boot.
5.
Continue with any message to proceed.
The DeviceNet card will display the power-up and revision
information. Next, it should display the node address of "30"
among other possible messages.
The card will not be communicating with the computer now
(because the computer is not at the new baud rate).
6.
Select
CLOSE
.
7.
Select
UTILITIES
.
8.
Select
GO OFFLINE
.
352-(&7²52%27
Follow these steps:
1.
Bring up
PROJECT FILE
.
2.
Select "
dnet\scanner\testfix\testfix.pc1
".
3.
Click on
ROBOT
to highlight it.
4.
Select
UTILITIES
.
5.
Then, select
SETUP ONLINE CONNECTION
. Go on-line
using node 62 and 500 kB/sec.
6.
Select
GO ONLINE
and then
YES
. Note that the project line
now reads, "
ROBOT Online
."
7.
On the project window, highlight the node 30 line by clicking
on it.
CURRENT NODE SETTINGS
NEW NODE SETTINGS
NODE ADDRESS
NODE ADDRESS
00 (As on MINI WHO)
30
CURRENT DATA RATE
DATA RATE
125kbps
125kbps
CURRENT NODE SETTINGS
NEW NODE SETTINGS
NODE ADDRESS
NODE ADDRESS
00 (As on MINI WHO)
30
CURRENT DATA RATE
DATA RATE
125kbps
500kbps
Содержание MedWeld 3005
Страница 2: ...YY UTGU T UbQd_bµc 7eYTU V_b D 1 bY ...
Страница 84: ...3_ e YSQdY_ c Q T 9 UTGU T UbQd_bµc 7eYTU D 1 bY ...
Страница 110: ...GU T CSXUTe Uc UTGU T UbQd_bµc 7eYTU D 1 bY ...
Страница 126: ...1TfQ SUT C_VdgQbU 6UQdebUc UTGU T UbQd_bµc 7eYTU D 1 bY ...
Страница 144: ...CUde QbQ UdUbc UTGU T UbQd_bµc 7eYTU D 1 bY ...