A P P E N D I C E S
page A – 30
WheatNet-IP
/ Apr 2009
In the WheatNet-IP GUI, you will need to define two new signals for the logic
function. You will need a logic source signal, representing the button, and a logic
destination signal, representing the DUMP connections on the airTools Delay unit. First
click on BLADE #5 in the System Pane of the GUI to open the tab windows for
BLADE #5. Click on the Sources tab to open the sources window, and click on the ADD
button to open the Signal Definition Wizard. Click on LIO only as the signal type and give
this new signal a convenient name such as “Dump Sw.”
On the LIO Info tab of the Wizard, click on the ADD box. Click on the “LIO 1 pin 4,”
and then select Input in the Direction: box as the logic direction (the DUMP switch will
be a logic Input). Finally open the logic function drop down menu and choose a logic
function. As mentioned
previously, the logic func-
tion chosen is unimpor-
tant, the requirement is
that the device you wish
to control must also use
the same function. In this
case choose “User 1” as
the function; you can re-
name it as “DUMP” if you
like. Click Apply, click
Close, then click Finish,
and the new logic source
signal definition is com-
plete.
Click on the System
icon and Crosspoint tab to
open the crosspoint grid;
you should see your new
“Dump Sw” signal source.
Содержание WheatNet-IP Blade3s
Страница 2: ...TECHNICAL MANUAL Wheatstone Corporation April 2009 AUDIO OVER IP NETWORK WheatNet IP ...
Страница 13: ...Quick Start 7 WheatNet IP Apr 2009 Figure 4 ...
Страница 224: ...A P P E N D I C E S page A 34 WheatNet IP Apr 2009 Appendix 5 Contents External Controllers A 35 ...
Страница 238: ...page A 48 WheatNet IP Mar 2014 A P P E N D I C E S Click Next Click Install ...