W H E A T N E T - I P
N A V I G A T O R G U I
page 4 – 5
WheatNet-IP
/ Apr 2009
Clock Master, a BLADE wave image will be overlaid on the icon (more on
System Master and Clock Master later). If the BLADE is a mix engine
BLADE, then the icon will show a control surface icon attached to it, with the
IP address of the corresponding control surface. If the BLADE is a streaming
PC BLADE, say one of your Automation Playback machines, the icon will
change to represent a PC. Note that for a PC to become a part of a
WheatNet-IP system and work with WheatNet-IP audio streams it must first
have the WheatNet-IP PC driver software installed on it. Information about
this is provided in the appendix of this manual.
If there are too many BLADEs in your system to all show at once in the
system pane, you can use a scroll bar on the right side of the pane to move
through the list of BLADEs.
Now take a moment and temporarily unplug the
network connection from one of your BLADEs. You’ll
notice in the system pane window of the GUI, the icon of
that BLADE has been overdrawn with a yellow question
mark. This is to let you know that a BLADE was a
member of your system but has become unavailable. If
you ever see this during normal system operation, look
for an unplugged network cable, or check to see if the
power has been removed from a BLADE or a network
switch. A short time after you plug the network cable
back into the switch, the yellow question mark will
disappear, indicating that the BLADE is available again.
To illustrate the dynamic nature of the WheatNet-IP
system, quit the GUI by clicking in the close box at the
upper right corner of the GUI window (not the system
pane window, please). Unplug one of the BLADEs and
relaunch the Navigator GUI. Once the discovery process
has been completed, if you check the system pane, the
BLADE you unplugged will be missing from the list, as
will all of its sources and destinations. Plug the BLADE
back in, and after a short while, the BLADE and its
sources and destinations will automatically get added
back in. You have a dynamic network.
Now let’s get back to the tabs.
Содержание WheatNet-IP Blade3s
Страница 2: ...TECHNICAL MANUAL Wheatstone Corporation April 2009 AUDIO OVER IP NETWORK WheatNet IP ...
Страница 13: ...Quick Start 7 WheatNet IP Apr 2009 Figure 4 ...
Страница 224: ...A P P E N D I C E S page A 34 WheatNet IP Apr 2009 Appendix 5 Contents External Controllers A 35 ...
Страница 238: ...page A 48 WheatNet IP Mar 2014 A P P E N D I C E S Click Next Click Install ...