Off Tally – logic output used to provide a tally of the fader’s OFF button to a re-
mote location
Remote On – logic input used to turn the fader on from a remote location
Remote Off – logic input used to turn the fader off from a remote location
Cough – logic input used to unassign the fader from its output bus while a switch
at a remote location is pressed, allowing talent at a microphone the chance to cough
(or make some other sound) without it being heard on air
Talk Back – logic input used to assign the fader to the surface cue audio while a
switch at a remote location is pressed, so talent at a microphone can talk directly
to the board operator
2. These functions are programmed on logic-only destinations to control the timer on
a surface. The logic-only destination must be routed to the surface source signal (ex-
ample: E6TIMER on an E-6) that has the timer logic pre-programmed on it.
Start Timer – logic input to start a surface timer from a remote location
Stop Timer – logic input to stop a surface timer from a remote location
Reset Timer – logic input to reset (set to zero) a surface timer from a remote location
Hold Timer – logic input to hold a surface timer at its current setting from a remote
location
3. These functions are programmed on logic-only destinations to interface with the
Silence Detect functions. The logic-only destination must be routed to the logic signal
that is automatically created when an output is enabled for Silence Detect. See the sec-
tion on Silence Detect starting on page 4-52 of this manual for more details.
SDet Failure – logic output to indicate when an output set for Silence Detect is in
a failed state; that is, when the primary source fails to provide audio to that output
SDet Mux Pos – logic output to indicate when an output set for Silence Detect is
using its backup audio source
SDet Force Pri – logic input to force an output with Silence Detect enabled to its
primary source
SDet Force Sec – logic input to force an output with Silence Detect enabled to its
backup source
4. These functions are currently undefined.
Take Preset n (where n = any integer between 1 and 10 inclusive)
5. These functions are programmed on logic-only destinations to indicate when certain
sources on the surface have their fader on. The logic-only destination must be routed
to the surface source signal (example: E6TALLY on an E-6) that has the tally logic
pre-programmed on it. Sources that will trigger the surface tallies are set in the surface
VDip settings (see the manual for the control surface type you are using).
Studio n In-Use (where n = any integer between 1 and 12 inclusive) – logic output –
the numbers 1, 2, 3, and 4 correspond to tallies 1, 2, 3, and 4, respectively – use of
the remaining values for n
is currently undefined
Содержание WheatNet-IP Blade3s
Страница 2: ...TECHNICAL MANUAL Wheatstone Corporation April 2009 AUDIO OVER IP NETWORK WheatNet IP ...
Страница 13: ...Quick Start 7 WheatNet IP Apr 2009 Figure 4 ...
Страница 224: ...A P P E N D I C E S page A 34 WheatNet IP Apr 2009 Appendix 5 Contents External Controllers A 35 ...
Страница 238: ...page A 48 WheatNet IP Mar 2014 A P P E N D I C E S Click Next Click Install ...