7-3
Table 7-1: Parameters
Parameter
Min
Max
Default Units
1
Area
15 column alpha- numeric field
2
Amp Id
15 column alpha numeric field
3
Power Configuration
IN / OUT / THROUGH
4
Feeder Maker Config
1
9
1
5 Trunk
Termination
NO
YES
NO
6
Voltage Setting
LOW / MID / HIGH
7 Reverse
Pad
-100.0 +100.0 0.0
dB
8 Reverse
Equalizer
-100.0 +100.0 0.0
dB
9
Forward Pad
-100.0 +100.0 0.0
dB
10 Forward Equalizer
-100.0 +100.0 0.0
dB
Table 7-2: Parameters versus Test Location Types
Parameters
Trunk Head
Extender
Fiber
Field
1 Area
yes
yes
yes
yes
2 Amp ID
yes
yes
yes
3 Power
Configuration
yes
yes
yes
4 Feeder
Maker
Configuration
yes
yes
yes
5 Trunk
Termination
yes
yes
yes
6 Voltage
Setting
yes
yes
yes
7 Reverse Pad
yes
yes
yes
8 Reverse
Equalizer
yes
yes
yes
9 Forward Pad
yes
yes
10 Forward Equalizer
Yes
Yes
7.2.2 Creating and Editing Test Locations
Use the up/down arrow keys to select
Test Location
, then press any
soft key, and Figure 7-2A,
Test Locations
list, appears.